Batteries & storage guide

Energy Storage Compared: Batteries, Pumped Hydro, Hydrogen

Pumped hydro, hydrogen, compressed air, heat stores, flow batteries, sodium-ion and lithium-ion (LFP) set against each other on cost, efficiency, duration and lifetime.

Updated 8 min read 1,794 words

In most places wind and solar are the cheapest new power. Their output follows the weather, though, not demand. Storage fills the gap, whether for milliseconds (frequency control) or months (seasonal swings). Since no single technology handles all of them at a sensible price, the useful question is which one suits which duration. The yardsticks are cost per kW and per kWh, round-trip efficiency, duration, lifetime and maturity.

Terms you need

  • Power capacity (MW): the highest charge or discharge rate.
  • Energy capacity (MWh): the amount that can be held.
  • Duration (h) = energy / power.
  • Round-trip efficiency (RTE): energy out / energy in.
  • Cycle life and calendar life: the cycles and years before capacity fades.
  • Levelised cost of storage (LCOS): lifetime cost per MWh delivered.
LCOS (€/MWh) = [CAPEX × CRF + fixed O&M] / annual MWh discharged + charging price / RTE + variable O&M

Annual MWh discharged = energy capacity × cycles per year × depth of discharge × (1 − average degradation)

Technology by technology

Technology Duration Round-trip efficiency Service life Installed cost, indicative (2024–25) Status
Lithium-ion (LFP), grid 1–4 h (up to 8) 85–92% 15–20 yrs / 6,000–10,000 cycles $150–350/kWh system (lower in China) Mass market
Lithium-ion (NMC) 1–4 h 85–90% 10–15 yrs / 3,000–5,000 cycles Similar; losing share to LFP Mature
Sodium-ion 1–4 h 80–90% 10–15 yrs (emerging data) Potentially below LFP Early commercial
Vanadium redox flow 4–12 h 65–80% 20–25 yrs, unlimited cycles $300–600/kWh Commercial, niche
Iron-air ~100 h 40–50% 20+ yrs Targets ~$20/kWh First deployments
Pumped hydro 6–24 h+ 70–85% 50–100 yrs $1,500–4,000/kW; $50–200/kWh Very mature
Compressed air (CAES) 8–24 h 40–70% (higher for adiabatic) 30–50 yrs $1,000–2,000/kW Few plants
Liquid air (LAES) 4–24 h 50–60% 30–40 yrs Similar to CAES Demonstration
Thermal (molten salt, CSP) 6–15 h ~40% elec→elec; ~95% heat 30 yrs $20–40/kWh_th Mature with CSP
Thermal (sand, brick, water for heat) Hours–seasons 50–95% (heat) 20–40 yrs Low per kWh_th Commercial for heat
Hydrogen (electrolysis + caverns + turbine) Days–seasons 30–45% 20–30 yrs High per kW, very low per kWh stored Pilot for power
Flywheels Seconds–minutes 85–95% 20 yrs High per kWh Niche
Supercapacitors Seconds 90–95% 1 million cycles Very high per kWh Niche

Treat the cost ranges as indications, because project size and region move them a lot; NREL ATB, PNNL and BNEF are among the sources.

Lithium-ion, the workhorse

Within about ten years lithium-ion moved from phones to power grids. BloombergNEF’s survey recorded a drop of about 20% in average pack prices during 2024, to around $115/kWh. Packs for stationary use cost less, with Chinese LFP cells changing hands well below $60/kWh. Inverters, containers, controls and the grid connection push the system price higher, yet large 4-hour projects outside the US are now commonly quoted turnkey at $150–250/kWh, with China lower still.

Growth is rapid. IEA data show power-sector battery additions roughly doubling in 2023; each year the new battery capacity is many times what is added in pumped hydro. California, Texas, China, Australia, the UK and Chile lead.

LFP (lithium iron phosphate) now dominates stationary storage. Set against NMC, it costs less, needs no cobalt or nickel, survives more cycles and resists overheating better. Its lower energy density barely matters when the container simply sits on the ground.

Jobs for batteries on the grid:

  • Frequency response (sub-second), the first and most lucrative market.
  • Energy arbitrage: charging from the midday solar surplus and selling into the evening peak.
  • Capacity or peak shaving, replacing gas peakers.
  • Congestion relief, which postpones grid upgrades.
  • Black start and grid-forming services, where newer inverters can steady weak grids.

Example: a 100 MW / 400 MWh battery

  • Installed cost of $220/kWh gives $88 million. Over a 20-year life at 7% WACC, the CRF is 0.0944, so capital is $8.3 m/yr, plus O&M of $2.5 m/yr.
  • One full cycle a day for 330 days, at 90% depth and ~90% average capacity retention: 400 × 330 × 0.9 × 0.9 ≈ 107,000 MWh discharged a year.
  • Capital plus O&M per MWh: $10.8 m / 107,000 ≈ $101/MWh.
  • Charging at $30/MWh with 88% RTE adds $34/MWh.
  • LCOS ≈ $135/MWh. Revenue covers the cost when the average discharge-minus-charge price spread, together with ancillary income, tops that figure.

Where solar is abundant, as in California, Australia and Spain, the price difference between midday and evening is more and more often $100–200/MWh. That explains the large-scale battery build-out in those markets.

Batteries for the home

A typical home battery holds 5–15 kWh and delivers 3–10 kW. Its jobs: raising self-consumption of rooftop solar, providing backup in some installations and exploiting time-of-use tariffs.

Annual saving ≈ extra self-consumed kWh × (retail price − export price) + arbitrage value

Example: 10 kWh battery, 250 useful cycles × 8 kWh = 2,000 kWh/yr × (€0.30 − €0.07) = €460/yr (minus ~10% round-trip losses ≈ €415)

At an installed cost of €5,000–7,000, the simple payback here is roughly 12–17 years. A subsidy, a dynamic tariff, costly retail power or a poor export rate all bring it down. Your own roof and tariff can be tested with the solar battery calculator and the solar panel calculator used together.

Pumped hydro, the long-lived giant

Pumped storage hydropower (PSH) provides roughly 190 GW worldwide (IHA) and still accounts for most stored energy on the planet. In cheap hours, pumps lift water from a lower reservoir to an upper one; when electricity is needed, it falls back through turbines.

Stored energy (kWh) = ρ × g × V × H × η / 3.6×10⁶

1 million m³ at 300 m head, 90% generating efficiency: 1,000 × 9.81 × 10⁶ × 300 × 0.9 / 3.6×10⁶ ≈ 736 MWh

A site needs suitable terrain, construction takes 5–10 years and costs billions, but the plant can last a century. Most new builds are in China, where over 50 GW is operating and much more is under construction. The Australian National University’s global atlas has mapped many off-river “closed-loop” sites, which affect the environment less. Use the pumped hydro storage calculator for a first sizing.

Storage for 8 hours and longer

Once renewables supply more than 60–70%, grids need storage to bridge nights, windless days and weather fronts. The leading candidates:

  • Flow batteries separate power (the stack) from energy (electrolyte tanks), so extra hours are cheap to add. Vanadium is furthest along; zinc-bromine, iron and organic chemistries lag behind. Several vanadium projects above 100 MWh have started operating in China.
  • Iron-air batteries store energy for ~100 hours through the rusting and un-rusting of iron, a very low-cost material. Form Energy started its first US utility deployments in 2024–2025.
  • Compressed air in salt caverns: Huntorf (Germany, 1978) and McIntosh (Alabama, 1991), with new adiabatic plants in China and Canada.
  • Gravity storage with blocks or mine shafts, mostly still at demonstration stage.
  • Thermal storage in sand, rock or molten salt can supply heat directly, which is very efficient, or be converted back to electricity, which is not.

Seasonal storage: hydrogen and heat

Shifting summer solar to winter means holding vast amounts of energy cheaply, so cost per kWh matters and efficiency matters less. Capacity in salt-cavern hydrogen storage runs at about $1–2 per kWh or less, a fraction of battery cost; the catch is that 55–70% of the energy disappears in the round trip. Germany and the Netherlands are developing cavern hydrogen storage. Seasonal heat storage is already commercial in district heating: water pits with insulated lids in Danish towns like Vojens, and underground borehole stores. See Green Hydrogen Explained and the green hydrogen calculator.

Choosing a technology by task

Task Best fit today
Frequency regulation (seconds) Batteries, flywheels
Shifting solar to the evening (2–6 h) LFP batteries
Overnight / daily cycle (6–12 h) Pumped hydro, LFP (longer durations), flow batteries
Multi-day lulls (1–7 days) Pumped hydro, iron-air, CAES, demand response, interconnectors
Seasonal Hydrogen, reservoir hydro, firm generation, seasonal heat storage
Home solar self-consumption 5–15 kWh LFP battery, hot water tank, EV

Storage also competes with other flexibility: demand response, interconnectors, smart EV charging and flexible generation. Cheap “thermal batteries” already exist in many homes, as a hot water tank or a heat pump with a buffer tank, and an EV carries 50–100 kWh.

Lessons from large grids

  • California. CAISO, the state grid operator, counts a few hundred MW of grid-scale batteries in 2020 and well over 10 GW by 2024–2025. Many summer evenings now see batteries as the single largest supplier for a few hours. They hold back surplus midday solar and release it at the evening peak, which replaces gas-fired generation.
  • Texas (ERCOT). The market pays nothing for capacity, but volatile prices and ancillary services were enough for batteries to boom, and on several summer peaks they have helped the grid stay out of emergency conditions.
  • Australia. In South Australia the Hornsdale Power Reserve, commissioned in 2017 at 100 MW and later expanded to 150 MW, proved that fast-reacting batteries lower the price of frequency control. Rooftop solar penetration is among the highest in the world, and many 2–4 hour batteries are in the pipeline to fill the gap left by retiring coal.
  • United Kingdom. Batteries first gained share in fast frequency response and then moved into energy trading as that market saturated. Other countries have since repeated this sequence.
  • China is the largest market for new grid storage. New solar and wind farms must include storage under provincial rules, and stand-alone LFP plants are multiplying.

One pattern recurs. Early batteries in any market are paid well for ancillary services, yet those markets are small and saturate fast. In the long run, income comes from energy arbitrage and capacity value, and both rise with the share of solar and wind.

Safety and sustainability

Battery fires are rare but serious. Compared with NMC, LFP is much less likely to go into thermal runaway. Current containers add gas detection and fire suppression and follow spacing standards (NFPA 855, IEC 62933). Material worries over lithium, cobalt, nickel and graphite are less pressing with LFP and sodium-ion chemistries, while the EU Battery Regulation is pushing recycling capacity upward. Pumped hydro’s footprint is mainly land and water.

Conclusion

Ten years ago storage was a bottleneck; today it no longer is. Where the sun is strong, lithium-ion has become cheap enough to shift solar output into the evening peak, and no other grid technology is being installed as quickly. For long durations, pumped hydro still carries most of the load. Flow batteries, iron-air, compressed air and thermal stores are competing for the 8–100 hour range. Seasonal balancing will probably rely on a mix of hydro, interconnection, hydrogen and firm low-carbon power. The world energy map puts national grids side by side; a household can begin with the solar battery calculator.

Calculators related to this topic

Frequently asked questions

Which storage technology is cheapest?
It turns on the duration. For 1–4 hours, lithium-ion, LFP above all, is usually the cheapest and fastest to build. Past 8–24 hours, pumped hydro and certain thermal systems tend to offer cheaper kWh of capacity. Seasonal storage favours hydrogen in salt caverns, the cheapest per kWh stored even though it returns little of what goes in.
What is the round-trip efficiency of different storage types?
Lithium-ion systems reach 85–92% measured AC to AC. Expect 70–85% from pumped hydro, 65–80% from flow batteries, 40–70% from compressed air and just 30–45% from hydrogen (power to gas and back to power).
What is the lifespan of a grid battery?
LFP systems normally come with 10–20 year warranties or 4,000–10,000 full cycles, guaranteeing 60–80% of capacity. A pumped hydro plant can operate for 50–100 years if refurbished from time to time.
Does a home battery pay for itself?
Three factors decide: the difference between your retail and export prices, how much solar you would otherwise send to the grid, and the battery's price. With a battery, the share of rooftop solar you use yourself rises from around 30–40% to 60–80%. Payback still often takes 8–15 years unless time-of-use tariffs or a subsidy help.
How do kW and kWh differ for storage?
Power (kW) is the speed of charging or discharging; energy (kWh) is the amount held. Energy divided by power gives duration, so a 100 MW / 400 MWh battery can run at full power for four hours.
How much storage would a renewable-heavy grid need?
No single number exists. A grid dominated by wind and solar typically wants a few hours of average demand in short-duration storage. Beyond that come longer-term and seasonal needs, met by hydro, interconnectors, demand response, hydrogen or dispatchable low-carbon plants.

Sources & references

  1. IEA (2024). Batteries and Secure Energy Transitions
  2. NREL — Annual Technology Baseline: Utility-scale battery storage
  3. BloombergNEF — Lithium-ion Battery Price Survey 2024 (summary)
  4. PNNL — Energy Storage Grand Challenge Cost and Performance Assessment
  5. International Hydropower Association — World Hydropower Outlook 2025 (pumped storage)

The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.