Heating guide

Heat Pump Guide: COP, SCOP, Running Costs and Sizing

How a heat pump works, what COP, SCOP and SPF tell you, how to compare running costs with gas, size a unit correctly and judge the payback.

Updated 9 min read 1,955 words

You will not find a flame in a heat pump. A compressor, powered by electricity, collects warmth that is already sitting in the air, the soil or a body of water and carries it into your house. Transporting heat costs far less energy than creating it, which is how one unit of electricity can bring in three to four units of heat. Decarbonisation plans for buildings lean on that ratio, and installations that fail to reach it account for most of the unhappy owners. What follows covers the physics, the efficiency figures that actually forecast your bill, how to choose a size, and how to set costs against gas, oil or plain electric heaters without cheating.

Four steps in a loop

The mechanism is the one in your fridge, and the same vapour-compression loop runs in a 20 MW district heating plant.

  1. Evaporator. Refrigerant that is colder than the air or ground outside runs through a heat exchanger and absorbs warmth. It still boils at −10 °C, since refrigerants like R290 (propane) and R32 have very low boiling points.
  2. Compressor. Squeezing the vapour pushes its temperature up to 50–80 °C.
  3. Condenser. The vapour now gives up its heat, either to heating water (air-to-water) or to room air (air-to-air), and condenses into a liquid.
  4. Expansion valve. Pressure drops, the refrigerant cools hard and is ready to start over.

Electricity is spent on the compressor and fans alone. Everything else you receive comes from the surroundings, which is the reason EU law counts heat pumps as renewable heat once seasonal efficiency passes a threshold.

Which type?

  • Air-to-water (monobloc or split). Takes heat from outside air; SCOP 2.8–4.0 in central Europe; €9,000–18,000 installed in a single-family home. It is Europe’s favourite and supplies radiators or underfloor heating plus hot water.
  • Air-to-air (split / multi-split). Also uses outside air, with SCOP 3.5–5.0 for heating and €2,000–8,000 installed. It costs least and can cool, but cannot make hot water.
  • Ground-source (borehole or horizontal loop). The ground sits at 8–12 °C; SCOP 3.5–4.8; €18,000–35,000. A steady source temperature is the benefit, and drilling is the main expense.
  • Water-source. Lake, river or groundwater gives SCOP 4.0–5.0, with prices that depend on the site, plus permits and a suitable water source.
  • Exhaust-air. Recovers heat from ventilation exhaust at SCOP 2.5–3.5 for €7,000–12,000, and fits small airtight homes.

These costs are indicative for European installs in 2024–2026 before subsidies, highest in the UK, Germany and Scandinavia and lower in Eastern Europe. Soil type affects how deep boreholes must go; the ground source heat pump calculator gives an estimate.

Reading the efficiency labels

COP (coefficient of performance) divides the heat delivered by the electricity used at a given moment.

COP = Q_heat / W_electric

Carnot limit: COP_max = T_hot / (T_hot − T_cold) (temperatures in kelvin)

What the Carnot expression tells you is that temperature lift beats every other factor. Take water heated to 35 °C (308 K) from air at 7 °C (280 K): the ceiling is 308 / 28 ≈ 11. Actual machines achieve roughly 40–55% of the ceiling, which puts COP near 4.5–5. Ask for a 55 °C flow and the ceiling sinks to about 6.8, with a real COP of around 3. Each degree you take off the flow temperature adds roughly 2–3% to efficiency.

SCOP (seasonal COP) comes from the EN 14825 test method. Test labs model one heating season in a reference climate (average, colder or warmer) at a fixed flow temperature, 35 °C “low temperature” or 55 °C “medium temperature”. You will see the weighted result on the EU energy label. Handy for ranking products, but it is a lab estimate.

SPF (seasonal performance factor) is the real-world version: total heat produced over a year divided by total electricity used, counting defrost cycles, circulation pumps, backup heaters and hot water. Field monitoring is the honest yardstick. Over several years, Fraunhofer ISE tracked heat pumps in existing and partly renovated German homes. Most air-source systems landed between about 2.6 and 4.0 SPF, on average 3.1–3.4, and ground-source systems averaged about 4. The best results always came from low flow temperatures.

Design flow temperature against SPF (air-source / ground-source):

  • 35 °C (underfloor heating): 3.5–4.2 / 4.3–5.0.
  • 45 °C (large radiators): 3.0–3.6 / 3.8–4.5.
  • 55 °C (standard radiators): 2.5–3.1 / 3.3–3.9.
  • 65 °C+ (old system left unmodified): 2.0–2.6 / 2.8–3.3.

Domestic hot water needs 50–55 °C all year and is produced at a COP of 2.5–3.2. Where insulation is good and hot water is a big share of demand, that lowers the annual figure a little.

Will it cost less than gas?

Three variables set the bill: the heat the building needs, the efficiency of whatever supplies it and the price of the energy. To keep a comparison with a gas boiler honest:

Annual cost (heat pump) = Heat demand (kWh) / SPF × electricity price

Annual cost (gas boiler) = Heat demand (kWh) / η_boiler × gas price + standing charge

Break-even price ratio = SPF / η_boiler

Use SPF 3.2 and a boiler at 0.90, a fair figure for a condensing boiler in an existing house (the 98% on the box rarely holds up). Break-even then sits at 3.2 / 0.9 ≈ 3.6: below that ratio of electricity to gas price per kWh, the heat pump is the cheaper option. If the gas connection goes altogether, you also save the standing charge, frequently €100–300 a year.

Electricity-to-gas ratios in household prices around 2025, judged at SPF 3.2:

  • UK, ~4.0: about break-even, and ahead on a heat pump tariff.
  • Germany, ~3.0–3.5: a heat pump has the lower bill.
  • France, ~2.0–2.3: clearly cheaper.
  • Sweden and Norway: little gas is available, so heat pumps dominate.
  • Romania and Hungary, ~4–6 (regulated gas): gas often has lower running costs.

Tariffs and policy move these ratios. For up-to-date prices open the country pages, then try your own case in the heat pump vs gas boiler calculator.

A German example: 140 m²

Suppose a partly renovated 1980s house needs 15,000 kWh of heat a year for rooms and hot water. It has an air-to-water heat pump with radiators designed for a 50 °C flow, and a measured SPF of 3.3. Electricity costs €0.34/kWh (about €0.28/kWh on a heat pump tariff), gas €0.11/kWh with a €150/year standing charge, and the boiler runs at 0.90 seasonal efficiency.

  • Gas boiler: 15,000 / 0.90 = 16,667 kWh of gas × €0.11 = €1,833 + €150 = €1,983/year.
  • On the standard tariff, the heat pump costs: 15,000 / 3.3 = 4,545 kWh × €0.34 = €1,545/year, which saves €438.
  • On the heat pump tariff: 4,545 × €0.28 = €1,273/year, which saves €710.

Assume the heat pump costs €12,000 net after a 30–50% subsidy, against €4,000 for a new gas boiler. The extra €8,000 then repays in roughly 11–18 years from energy savings alone. Higher carbon prices will bring that down (the EU ETS2 covers building fuels from 2027–2028), while rooftop solar moves part of the consumption to free daytime power (the solar panel calculator estimates how much). The heat pump calculator takes your own inputs.

Getting the size right

Installers sometimes replace a 24 kW boiler with a 16 kW heat pump “just to be safe”, and that is an error. Oversized units start and stop constantly, lose efficiency at part load and cost more to buy. Boilers were routinely two to three times oversized because that was nearly free. Aim instead for the building’s design heat loss:

Heat loss (W) = [ Σ(U × A) + 0.33 × n × V ] × (T_inside − T_design)

U = thermal transmittance (W/m²K), A = element area (m²) n = air changes per hour, V = heated volume (m³)

Typical specific heat loads at a −10 °C design temperature, with the result for a 140 m² house:

  • Passive house: 10–15 W/m², or 1.5–2 kW.
  • New build (post-2015 EU): 25–40 W/m², or 3.5–5.5 kW.
  • Renovated 1970s–1990s: 50–70 W/m², or 7–10 kW.
  • Unrenovated pre-1970: 90–130 W/m², or 13–18 kW.

Existing houses allow a shortcut. Convert three years of gas bills into heat by multiplying by boiler efficiency, then divide by the full-load heating hours where you live (about 1,800–2,400 h in central Europe). For example, 20,000 kWh gas × 0.9 / 2,000 h ≈ 9 kW.

Cut demand first. Insulating the loft and cavity walls typically reduces heat loss by 20–35%, so a smaller and cheaper unit can run at a lower flow temperature. Good starting points are the home insulation guide and the insulation savings calculator.

Practical ways to boost efficiency

  • Set the flow temperature as low as comfort allows, and enable weather compensation so it follows the outdoor temperature.
  • Let it run low and slow. Continuous low output is where heat pumps are most efficient, whereas steep night setbacks force a hot recovery in the morning.
  • Keep the hydraulics simple. Remove unneeded thermostatic valves in main living areas and leave out buffer tanks unless the design needs one; each added exchange or mixing step costs efficiency.
  • Fix the weakest radiators. Two or three rooms usually set the flow temperature, and bigger or fan-assisted radiators there can lower it by 5–10 °C.
  • Control the backup heater. An electric immersion or flow heater at COP 1 can quietly ruin seasonal performance, so permit it only below the bivalent point.
  • Measure. For a few hundred euros, a heat meter plus an electricity sub-meter will tell you your real SPF.

Climate impact

Emissions follow the electricity. Suppose the grid emits 460 g CO₂/kWh, roughly the 2025 world average (Ember / Our World in Data). At SPF 3.2 each kWh of heat then carries about 145 g CO₂, whereas a gas boiler emits about 225 g (≈ 202 g/kWh of gas at 90% efficiency). On cleaner grids the gap becomes enormous: with French power (~40 g/kWh) the figure is only about 13 g per kWh of heat. A low-efficiency heat pump gets near gas only on very coal-heavy grids above roughly 650–700 g/kWh. For your own country, open carbon intensity of electricity or run the electricity CO₂ calculator.

According to the IEA, heat pumps rolled out in line with national pledges could prevent at least 500 million tonnes of global CO₂ by 2030. It puts their emissions at least 20% below gas boilers even where the grid leans on gas, and up to 80% lower on clean grids.

Myths worth dropping

  • “Heat pumps can’t handle cold.” Norway, Sweden and Finland have the highest heat pump penetration in Europe. Efficiency does decline in the cold but the machines carry on, as heat pumps in cold climates explains.
  • “Only underfloor heating will do.” It helps, but most radiator systems cope at 45–55 °C after modest upgrades.
  • “You need a passive house.” A correctly sized unit can heat any house, and insulation just makes buying and running it cheaper.
  • “It’s an electric heater in disguise.” Resistance heaters have a COP of 1; a heat pump supplies 2.5–5 times as much heat per kWh.

The takeaway

Among electric heaters the heat pump is the most efficient by far, and a well-installed system across most of Europe and North America is already cheaper to run than gas. Two inputs you control settle the economics, namely flow temperature (which fixes SPF) and electricity tariff, along with one you mostly cannot, the gas-to-electricity price ratio. Start with a proper heat-loss calculation, fix obvious insulation gaps, and ask installers for guaranteed seasonal performance, not peak COP. After that, use the heating cost comparison to set all the alternatives side by side.

Calculators related to this topic

Frequently asked questions

Which COP counts as good for a heat pump?
Around 4–5 is typical for current air-to-water units under standard test conditions (7 °C outside, 35 °C flow). Look at the seasonal number instead, though: low flow temperatures and good design give an SCOP of 3.0–4.0 in central Europe, and ground-source systems usually 3.5–4.5.
Is heating with a heat pump cheaper than with gas?
The price ratio decides. A heat pump comes out ahead if a kWh of electricity costs less than SCOP divided by boiler efficiency, times the price of a kWh of gas. Try an SCOP of 3.2 against a boiler at 90%. Electricity could be priced at as much as roughly 3.6 times gas and the heat pump would still break even.
Can a heat pump run radiators?
Usually yes. What matters is how hot the radiator water must be on the coldest day. Many existing radiator circuits were oversized and can heat the house at 45–55 °C, and swapping a few undersized radiators generally costs much less than fitting underfloor heating.
What is the lifespan of a heat pump?
An air-source unit typically runs 15–20 years. With ground-source, the buried loop can last 50 years or longer while the heat pump itself lasts around 20. Yearly upkeep is light and covers pressure, filters and controls.
How do I choose the right heat pump size?
Base it on the heat the building loses at your local design outdoor temperature, and ignore the old boiler's rating. In central Europe a well-insulated 120 m² house usually needs 5–8 kW, and an older uninsulated one 12–16 kW. Only a calculation room by room will give a trustworthy answer.
Do heat pumps make a lot of noise?
At 1 metre and normal load, a modern outdoor unit sounds like about 35–55 dB(A), similar to quiet conversation or a refrigerator. Where you put it matters. Keep it out of enclosed corners and away from bedroom windows, and look up local noise rules; UK permitted development, for instance, sets a 42 dB limit at a neighbour's window.

Sources & references

  1. IEA (2022). The Future of Heat Pumps
  2. Fraunhofer ISE — Field measurements of heat pumps in existing buildings (WPsmart im Bestand)
  3. EN 14825 — Air conditioners, liquid chilling packages and heat pumps: testing and rating at part load conditions and calculation of seasonal performance
  4. Energy Saving Trust — Electrification of Heat UK demonstration project
  5. IPCC AR6 Working Group III, Chapter 9 — Buildings

The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.