Leak repair: low cost, fast return
Few utilities cost a factory more per useful unit than compressed air. Heat takes 85–90% of a compressor’s electricity, and only 10–15% reaches the tool as work. Leaks make that worse because they run around the clock while the network holds pressure, weekends included, and nobody hears them over the machines. Plants with no leak programme typically waste a fifth of their air or more.
Enter what your survey found. You get back airflow, compressor load, annual kWh, cost and CO₂, along with the leak rate against capacity and a payback period for fixing them.
The formula
Across normal network pressures, air rushing out of a hole travels at sonic speed (choked flow). The result is a flow set by two things alone, hole area and upstream pressure:
A = π d² ÷ 4 p₀ = gauge pressure + 1.013 bar (absolute) γ = 1.4 R = 287 J/(kg·K) T = 293 K Free air flow Q = ṁ ÷ 1.204 kg/m³
Wasted power (kW) = Q (m³/min) × specific power (kW per m³/min) Annual cost = kW × pressurised hours × electricity price
Set C_d to 1 and the equation reproduces the Compressed Air Challenge benchmark (6.5 cfm from a 1/16” hole at 100 psig). Ragged real-world holes flow less, hence a default C_d of 0.65, near the DOE’s 0.61 for sharp-edged openings.
Worked example
Setup: a screw compressor at 6.5 kW per m³/min, 7 bar, 6,000 pressurised hours yearly. The survey counted 31 leaks in three sizes.
| Leak size | Count |
|---|---|
| 1 mm (small) | 20 |
| 2 mm (medium) | 8 |
| 3 mm (clearly audible) | 3 |
| Hole | Flow per leak | Power per leak | Cost per leak per year |
|---|---|---|---|
| 1 mm | 0.8 l/s (1.7 cfm) | 0.31 kW | ≈ 280 |
| 2 mm | 3.2 l/s (6.8 cfm) | 1.25 kW | ≈ 1,130 |
| 3 mm | 7.2 l/s (15.3 cfm) | 2.81 kW | ≈ 2,530 |
| 6 mm | 28.9 l/s (61 cfm) | 11.3 kW | ≈ 10,100 |
Totals for all 31 leaks: 63 l/s (3.8 m³/min, 134 cfm) and 24.7 kW of compressor power, which means 148,000 kWh a year. At 0.15/kWh that is about 22,200, with 68 t CO₂ at world-average grid intensity. A 15 m³/min compressor would be giving up 25% of its output, a typical level for an unmanaged network. Fixing each leak for 40 (1,240 overall) is recovered in under a month.
Diameter works as a square, so one 3 mm leak equals nine 1 mm leaks.
Reading the results
| Result | Use |
|---|---|
| Annual leak cost | The number for management, assuming lost air is replaced at the compressor’s average specific power. |
| Leak rate | Leak flow against capacity. Beyond 10% a programme is justified; at 20–30% a compressor may run just to feed leaks. |
| Cost of one 3 mm leak | Printable on repair tags to show what each leak costs. |
| Hole-size table | Flow and cost per hole size at your pressure. |
Further savings
| Action | Why it helps |
|---|---|
| Set pressure to the most demanding user’s real need | Each bar saved cuts about 7% of compressor energy and reduces leak flow |
| Solenoid valves on idle sections | Lines stop leaking when the shift ends |
| Stop using air for cooling, blowing off or drying | An open blow-off tube is a 6 mm leak made on purpose |
| Variable-speed or well-sequenced compressors | No unloaded running |
If you are also thinking about motor drives, open the motor energy savings calculator.
Limitations
Treat hole sizes as estimates; for firmer figures use a leak-down test or an ultrasonic detector that estimates flow. Specific power is an average, and a compressor at part load or unloaded burns more per m³, so real costs can run higher. The model skips compressor wear, extra capacity bought to cover leaks, and pressure drop where the air is used.
Method & assumptions
A leak passes a choked mass flow of ṁ = Cd A p0 √(γ ÷ RT) × (2 ÷ (γ+1))(γ+1)/(2(γ−1)), where p0 is the absolute pressure, γ = 1.4, R = 287 J/kg·K and T = 293 K. Dividing ṁ by 1.204 kg/m³ gives free-air volume. The power lost is free air (m³/min) × the compressor's specific power (kW per m³/min), and the annual cost is kW × hours the system is pressurised × electricity price.
Frequently asked questions
Yearly cost of one air leak
How much compressed air do plants lose to leaks?
How can I test a system for leakage?
What is the power cost of one cubic metre of compressed air?
Does lowering the pressure help with leaks?
Is fixing air leaks worth the money?
Sources & references
Embed this calculator