Payback is only the first filter
Plenty of efficiency projects live or die on simple payback alone, and sound ones get rejected. Returning the money in four years from a twenty-year asset can beat two years from a five-year asset. So the tool shows payback next to finance’s own yardsticks: net present value (NPV), internal rate of return (IRR), savings-to-investment ratio (SIR) and the cost of a saved kWh.
Anything that saves energy qualifies, from boiler upgrades, heat recovery and compressed-air repairs to controls, insulation, motors and drives and lighting. For fuel, give the saving in kWh and the fuel price per kWh.
Formulas
Simple payback = net investment ÷ first-year net saving NPV = Σ cash flow_t ÷ (1 + r)^t IRR = r at which NPV = 0 SIR = PV(savings) ÷ net investment Cost of saved energy = (net investment × CRF(r, life) + maintenance change) ÷ annual kWh CRF(r, n) = r(1 + r)^n ÷ ((1 + r)^n − 1)
Defaults worked through
Inputs: 25,000 invested, 60,000 kWh saved yearly at 0.15 per kWh, energy price rising 2% a year, savings fading 0.5% a year, 12-year life, 7% discount rate.
- First year: 60,000 × 0.15 = 9,000. Simple payback is 2.8 years; with discounting, 3.1.
- Twelve years deliver about 700 MWh, an NPV of roughly 51,700 and an IRR of 36%.
- SIR of 3.1: each unit spent returns about three in present-value terms.
- Cost per kWh saved: 25,000 × CRF(7%, 12) = 3,148 a year ÷ 60,000 kWh = 0.052, about a third of the energy price.
The other presets shift the picture. In the LED case, 1,500 a year of avoided lamp replacements trims payback to 2.4 years. Insulation takes 5.9 years but lasts 30, so its IRR is 19% and its NPV is comparable to LED. The controls preset shows savings that decay 3% a year.
Usual paybacks
Simple payback, then life:
- Compressed-air leak repair: weeks to months; 1–2 years (repeat).
- LED retrofit: 1–4 years; 10–15 years.
- Variable-speed drive on a pump or fan: 1–3 years; 10–15 years.
- Building controls / BMS tuning: 1–3 years; 5–10 years.
- Premium-efficiency motor when the old one fails: 1–3 years (incremental cost); 15–20 years.
- Heat recovery: 2–5 years; 15–20 years.
- Roof or wall insulation: 4–10 years; 30+ years.
What each result means
- Simple payback: easy to explain, blind to everything after break-even.
- NPV: the value added, expressed in present money. A positive figure outperforms keeping the cash at the discount rate.
- IRR: lets you rank the project against other uses of capital.
- Cost of saved energy: the neatest yardstick against your tariff or against supply-side options. The LCOE of new generation makes a good partner figure, since saving a kWh often beats building a “power plant”.
- Cumulative chart: break-even timing, discounted and undiscounted.
Boundaries
The cash flows ignore tax and debt. Depreciation for tax, interest and inflation have no separate inputs, so keep the discount rate and escalation on the same basis, both real or both nominal. Predicted savings tend to be optimistic; verify by metering. Rebound effects and interaction between measures (LEDs cut cooling load but add to heating, for example) are excluded. Where debt and tax matter, the NPV and IRR calculator goes further.
Method & assumptions
The model books a benefit every year t: kWh saved × (1 − decline)t−1 × price × (1 + escalation)t−1, less any change in maintenance. Year 0 is the outlay, −(investment − grants). Net investment divided by the first-year saving is the simple payback. All flows are discounted at the chosen rate to give discounted payback, NPV and IRR. SIR = PV of savings ÷ net investment, while the price of each saved kWh = (net investment × CRF(rate, life) + maintenance change) ÷ annual kWh.
Frequently asked questions
What is the payback formula for an efficiency upgrade?
Is a 3-year payback good enough?
Cost of saved energy: what is it?
What does a savings-to-investment ratio tell me?
Do I add energy price rises to the model?
How do I prove the savings happened?
Sources & references
Embed this calculator