Counting fuel by burnup
Reactors produce heat, as coal and gas plants do, but nobody quotes a calorific value per tonne of uranium. The yardstick is burnup: how many megawatt-days of heat each kilogram of uranium has delivered when it leaves the core. Combine thermal output, capacity factor and the burnup the fuel reaches, and the annual fuel demand is fixed.
From there the tool walks back through the fuel cycle. Each kilogram of enriched fuel starts as a larger mass of natural uranium, bought as U₃O₈ and converted to UF₆ before it is enriched. The enrichment itself is measured in separative work units (SWU). Attach a price to every stage and the front-end cost per MWh follows.
Equations
Natural feed F = P × (x_p − x_t) ÷ (x_f − x_t) x_f = 0.711 % Tails T = F − P SWU = P·V(x_p) + T·V(x_t) − F·V(x_f) V(x) = (2x − 1) · ln(x ÷ (1 − x))
U₃O₈ (kg) = F × 1.1792 1 kg = 2.2046 lb
V(x) is the standard measure of enrichment work and does not depend on the process, whether centrifuge or the gaseous diffusion of the past. Reactors on natural uranium, CANDU for one, need no enrichment, so the feed is simply the fuel loaded.
Worked case: a 1,000 MWe PWR
Default inputs: 33% net efficiency, 90% capacity factor, fuel enriched to 4.4% U-235 and burned to 45 MWd/kgU, tails at 0.25%.
A 1,000 MWe unit at 33% efficiency has to produce 3,030 MWt of heat (1,000 ÷ 0.33). Over a year at 90% load that is 995,500 MWd. Dividing by the 45 MWd/kgU burnup gives 22.1 tU of fresh fuel, roughly 48 assemblies of 460 kg each.
Back up the chain: the natural uranium feed is 22.1 × (4.4 − 0.25) ÷ (0.711 − 0.25), or 199 tU, which converts to 235 t of U₃O₈ (0.52 million lb). Enrichment costs 6.66 SWU for every kg of product, so the plant uses 147,000 SWU a year.
Price it with U₃O₈ at 80/lb, conversion at 60/kgU, enrichment at 170/SWU, fabrication at 350/kgU and a back-end fee of 1/MWh. The annual fuel bill is then about 94 million, or 11.9 per MWh.
To make the same 7.9 TWh, a coal plant at 38% efficiency would burn about 2.9 million tonnes; a modern combined-cycle gas plant would use about a million tonnes of LNG.
Factors that move the result
Burnup has the biggest effect. Industry raised burnup from 33 to 50 MWd/kgU between the 1980s and today, and that cut the yearly fuel load and the spent fuel by a third. Higher enrichment is needed to get there, so the saving in natural uranium is smaller. Efficiency counts as well: an older 33% unit burns about 10% more fuel per MWh than a Gen III+ reactor at 36–37% net. The tails assay is a matter of economics. When SWU is cheap and uranium dear, enrichers push tails to 0.20% or lower to save feed; the uranium enrichment calculator locates the optimum.
Reference values
| Reactor | Enrichment | Burnup (MWd/kgU) | Fuel per year per 1,000 MWe |
|---|---|---|---|
| PWR, current fuel | 4.0–4.95% | 45–60 | 18–25 tU |
| BWR | 3.8–4.5% | 40–55 | 20–27 tU |
| VVER-1000 | 4.0–4.9% | 45–55 | 20–25 tU |
| PHWR / CANDU | 0.711% (natural) | 7–8 | 130–150 tU |
| HTGR (pebble bed) | 8–17% | 80–160 | 8–12 tU |
Using the outputs
- Fuel loaded per year equals the fresh fuel entering the core and, by mass, the spent fuel leaving it.
- Natural uranium is the amount mining must supply. World output is about 50,000–60,000 tU a year, so a reactor fleet’s needs look small in tonnes.
- Separative work shows how much enrichment capacity the reactor ties up.
- Fuel cost per MWh adds the waste fee you entered to the front-end cost. Fuel is a minor part of nuclear generating cost, as capital dominates; the LCOE calculator shows the full picture.
Caveats
The result describes an equilibrium cycle. Real reloads vary from year to year because of first cores, cycle-length changes, uprates and outages. Conversion and fabrication losses (about 0.5% each) are ignored, as is the enrichment of reprocessed uranium or MOX. Prices for uranium, conversion and SWU follow long-term contracts and spot markets, so read the defaults as illustrative.
Method & assumptions
Start with thermal power: MWt = MWe ÷ efficiency. The heat produced in one year is MWd = MWt × 365 × CF, where CF is the capacity factor. Dividing MWd by the burnup in MWd/kgU gives the enriched uranium per year. For natural-uranium feed F, take the product P × (xp − xt) and divide by (xf − xt), with xf = 0.711%. Separative work equals P times V of the product assay, plus T times V of the tails assay, minus F times V of the feed assay (xf), where V(x) = (2x − 1) ln(x / (1 − x)). U₃O₈ = U × 1.1792; 1 kg = 2.2046 lb.
Frequently asked questions
What is the yearly uranium need of a 1,000 MW reactor?
How is burnup defined in nuclear fuel?
How much power can a kilogram of uranium generate?
What is the fuel cost of nuclear power per MWh?
How many assemblies are swapped at each refuelling?
How much spent fuel does a reactor discharge?
Sources & references
- World Nuclear Association — The Nuclear Fuel Cycle and Uranium Enrichment
- World Nuclear Association — Economics of Nuclear Power (fuel cost breakdown)
- IAEA — Nuclear Fuel Cycle Information System and Power Reactor Information System (PRIS)
- OECD NEA / IAEA — Uranium 2022: Resources, Production and Demand (Red Book)
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.