Solar calculator

Solar panel calculator with true hourly output, savings and payback

NASA satellite weather drives an hour-by-hour simulation of a full year at your precise spot. The energy is then converted into savings, a payback period and the CO₂ you avoid.

Live satellite data Editable share link Branded PDF report Free · no sign-up

Results

Why hourly weather beats peak sun hours

The common online shortcut is system size times an average count of peak sun hours. It hides nearly everything of importance: how the sun’s angle shifts through the seasons, clear days against cloudy ones, panel heat in July and how much of the output you can use at home. This tool does it properly. Pick a place and the tool fetches 8,760 hourly records from NASA’s POWER project, which derives them from satellites: global, direct and diffuse irradiance plus air temperature and wind. Your system is then run through every hour, much like professional yield software does.

Every hour, it goes through these steps:

  1. locate the sun in the sky for your coordinates;
  2. separate the measured sunlight into a direct beam, diffuse light from the sky and light bounced off the ground;
  3. transpose each part to the panel plane via the Hay–Davies sky model (with trackers, that plane follows the sun);
  4. deduct reflection losses at shallow incidence angles;
  5. get the cell temperature from irradiance, ambient temperature and wind, and lower the output by the temperature coefficient of your module technology;
  6. subtract system losses, apply inverter efficiency and clip whatever exceeds the inverter’s AC rating.

Summing the year gives production. Monthly bars and average-day curves are drawn from that same hourly data, so the seasonal shape you see is the local one, not a template.

Main equation

P_ac(t) = min( P_inv , kWp × G_eff(t) / 1000 × [1 + γ × (T_cell(t) − 25)] × (1 − losses) × η_inv )

G_eff = G_beam × IAM(θ) + G_diffuse + G_reflected (W/m² on the panel plane) T_cell = T_air + G_eff / (U0 + U1 × wind)

Symbols: γ stands for the power temperature coefficient, from −0.24 %/°C (heterojunction) to −0.40 %/°C (older polycrystalline). U0 and U1 capture module ventilation. The inverter efficiency η_inv is a 97% weighted value.

Example: 6 kWp on a Bucharest house

The defaults are 6 kWp of TOPCon modules tilted 32° due south, 14% losses and 2024 weather. They produce about 7,300 kWh a year. That is a specific yield near 1,220 kWh/kWp and a performance ratio around 77%. July yields roughly three times December.

Suppose 60% of the energy is used in the house at €0.25/kWh and the other 40% is exported at €0.06/kWh. A kWh is then worth about €0.174, and the first year saves around €1,270. Installed cost is €6,600, maintenance €60 a year and there is one inverter replacement in year 13. Payback is a little over five years, and the 25-year net return exceeds €30,000.

Reading the output

  • Annual production: first-year AC energy at the meter. Later years fall by the degradation rate (0.3–0.5%/year for modern modules).
  • Specific yield (kWh/kWp): compares sites and designs of any size.
  • Performance ratio (PR): the fraction of theoretical sunlight potential that reaches the grid. 75–85% is normal; lower points to heat, clipping or high losses.
  • Irradiation on panels: solar energy landing on one square metre of your tilted modules in a year.
  • Payback, IRR, NPV: the system measured against just buying power. An IRR above your mortgage or savings rate says the panels use the money better.
  • LCOE: the lifetime cost of each kWh from your roof, to set against your retail price.

Typical values

Location Optimal tilt Specific yield (fixed, south)
Oslo, Norway 40–45° 850–950 kWh/kWp
London, UK 35–40° 900–1,000 kWh/kWp
Berlin, Germany 35–38° 950–1,050 kWh/kWp
Bucharest, Romania 32–35° 1,200–1,300 kWh/kWp
Madrid, Spain 32–35° 1,550–1,700 kWh/kWp
Phoenix, USA 28–32° 1,750–1,900 kWh/kWp
Atacama, Chile 22–26° 2,100–2,400 kWh/kWp

Ways to improve results

  • Use more power yourself. Self-used kWh are worth the full retail price, while exported ones often earn a quarter of that. Shift dishwashers, water heating and EV charging to midday, or consider a home battery.
  • East–west roofs are fine. They give up 10–20% of annual energy but their wider daily curve fits household demand better.
  • Oversize the array a little. DC/AC ratios of 1.1–1.3 are routine. A cheaper inverter and extra output at the edges of the day and in winter more than offset the slight clipping.
  • Keep the modules cool. Leaving an air gap behind the modules on a rack keeps them several degrees cooler than flush mounting, which adds 2–4% energy in hot climates.
  • Verify the tilt. Wondering about a steeper or flatter mount? The solar tilt angle calculator gives the gain or loss.

Limitations

Shading from trees, chimneys or neighbouring buildings is not modelled. If part of the roof is shaded, increase the system-loss percentage accordingly. NASA POWER weather comes from satellites at about 50 km resolution, which smooths very local effects such as coastal fog or mountain valleys. Weather varies ±5–8% from year to year, and the weather year option lets you test that. Money results ignore taxes, financing and tariff changes other than the escalation rate you set.

Method & assumptions

The model walks through 8,760 hourly steps in the year you select. At each step it fixes where the sun is, then divides satellite irradiance among beam, diffuse and reflected light. Those parts are tilted onto the panel plane (Hay–Davies), and incidence-angle losses come off. Cell temperature is inferred from air temperature, wind and irradiance. Conversion to AC applies the module's temperature coefficient, your percentage losses, 97% inverter efficiency and a ceiling at the inverter's AC rating.

Cash side: (self-consumed share × retail price + exported share × export price) × production is the year-1 value. Later years see degradation and escalating prices; upkeep rises 2%/year and the inverter is replaced in year 13. You are paid back once cumulative net cash is above zero. LCOE = discounted lifetime cost ÷ discounted lifetime energy.

Frequently asked questions

What yearly output can I expect from a 6 kW solar system?
Mainly it depends on sunshine and orientation. For a well-aimed 6 kWp system expect roughly 5,000–6,000 kWh a year in Germany or the UK. In Romania or northern Italy the range is 7,000–8,000 kWh, and in Spain, Texas or Australia 9,000–11,000 kWh. Type your address above and the tool simulates a figure from real hourly weather.
What counts as a good specific yield (kWh/kWp)?
Specific yield means annual energy per kWp installed. Rules of thumb: below 900 kWh/kWp is weak (northern Europe, much shade, steep north-facing roofs); 1,000–1,300 is what central Europe usually sees; 1,400–1,700 counts as very good (Mediterranean, southern US); above 1,800 is outstanding (deserts, trackers).
Which way should panels point?
North of the equator, true south (azimuth 180°) gives the most energy over a year; south of it, true north. Roofs facing east or west normally give up just 10–20%, and they spread output over morning or evening, which can lift self-consumption.
What is the payback time for solar panels?
Across most of Europe a home system recovers its cost in 5–10 years if the household uses a big share of the power directly. Three things matter most: what a kWh costs you from the grid, how much of your output you use directly (exports usually pay much less), and the installed price per kWp.
Why does my result fall short of rated power multiplied by sun hours?
Several things eat into output: heat (roughly 0.3–0.4% lost for each °C over 25 °C), conversion in the inverter, cabling, dirt, mismatch between modules, and reflection when the sun sits low. A performance ratio of 75–85% is normal, and this tool models each of these losses hour by hour.
Can I use this calculator anywhere on Earth?
Yes. Satellite-derived NASA POWER weather covers every latitude and longitude, so the same method works for a balcony in Oslo or a solar farm in the Atacama.

Sources & references

  1. NASA POWER — Prediction Of Worldwide Energy Resources (hourly data API)
  2. Dobos, A. P. (2014). PVWatts Version 5 Manual. NREL/TP-6A20-62641
  3. Hay, J.E. & Davies, J.A. (1980). Calculation of the solar radiation incident on an inclined surface
  4. Faiman, D. (2008). Assessing the outdoor operating temperature of photovoltaic modules. Progress in Photovoltaics 16(4)
  5. IRENA — Renewable Power Generation Costs

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.