Heating & gas calculator

What will running a space heater cost you?

How much does a heater cost to run per hour, day and winter? Pick an electric model (oil-filled, fan, convector, infrared, ceramic), a split heat pump, an LPG cabinet heater or kerosene. The result also shows whether its power matches the room.

Editable share link Branded PDF report Free · no sign-up

Results

Expect this heater to cost about 0.42 € per hour on full power. At your usage that is 1.51 € daily, or 181 € for 120 days. With 1.5 kW of heat it can serve a 16 m² room needing about 1.1 kW.
Cost per winter
€181
648 kWh of electricity
Hourly cost at full power
€0.42
Cost per day
€1.51
6 h on, 60% duty cycle
Cost per month
€45.96
Cost per kWh of heat
€0.28
all input becomes heat
Heat output
1.5kW
room needs ≈ 1.1 kW
Fuel used per winter
648kWh
Delivering the same heat with each heater type: cost per winter

Price of each kWh of heat delivered

Heater€/kWh of heat
Oil-filled radiator0.28
Fan heater0.28
Convector / panel radiator0.28
Infrared / halogen radiant heater0.28
Ceramic heater0.28
Air-to-air heat pump (split air conditioner)0.088
LPG cabinet heater0.203
Kerosene / paraffin stove0.208
  • Whether oil-filled, fan, convector, ceramic or infrared, every electric resistance heater converts all its electricity to heat. If one is sold as “energy-saving”, the gain has to come from smarter controls or from warming people instead of air (infrared). Only a heat pump returns more heat than the electricity it draws.
  • LPG and kerosene heaters without a flue add water vapour, CO₂ and nitrogen dioxide to the air indoors. Ventilate when using them; in many countries they are prohibited in bedrooms.
  • Heat needed per m² of room at about −5 °C outside: roughly 100 W for poor insulation, 70 for average and 45 for good insulation.

What the calculator does

A heater is a simple device, so its running cost depends on only three things: the power it draws, the share of time it is actually switched on, and your price per kWh. Enter the input power and tariff and you get the hourly cost at full output. A duty cycle then scales that for thermostat cycling, and the result is extended to a day, a month and the whole cold season.

Two extra checks are included that most people skip. One sets the heater’s output against the heat your room needs in cold weather, given its area and insulation, so you can tell whether the unit will cope or run flat out all day. The other lines up every heater type delivering the same heat, which shows how little the choice among electric models matters, and why a heat pump belongs in another class.

Formulas

Cost per hour on full = input power (kW) × price per kWh (LPG: price per kg ÷ 12.8 kWh/kg; kerosene: price per litre ÷ 9.6 kWh/L) Real cost per hour = full-power cost × duty cycle Cost per day = real cost per hour × hours on Cost per winter = cost per day × days of use

Heat output = input × COP (COP = 1 for resistance and flame heaters) Room heat need = floor area × 45 / 70 / 100 W/m²

Sample calculation

The preset scenario: a 1.5 kW oil-filled radiator used 6 hours a day across 120 winter days, thermostat on 60% of the time, electricity at €0.28/kWh, and a 16 m² room of average insulation.

  • Full output costs 1.5 × €0.28 = €0.42 per hour.
  • Allowing for cycling, €0.42 × 0.6 gives €0.25 an hour, which is €1.51 a day.
  • Across the season that is €1.51 × 120 = €181, from 648 kWh (roughly €46 a month).
  • A kWh of heat costs €0.28, since all the electricity ends up as heat.
  • The room needs around 16 × 70 W = 1.1 kW when it is cold, leaving the 1.5 kW heater some headroom.

The comparison chart puts every resistance heater at the same €181. A split air conditioner heating at COP 3.2 would provide the same heat for about €57. At the preset fuel prices, an LPG cabinet heater costs about €132 and a kerosene heater €135.

Reading the results

  • Start with the seasonal total, which combines your daily hours with the duty cycle.
  • The full-power hourly figure is a ceiling, reached for example when a chilly room is first heated.
  • If the heater’s output sits below the room’s need, expect it to run non-stop on cold days without reaching the target temperature. Try a 100% duty cycle to price that scenario.
  • Price per kWh of heat is the number to compare against other systems; the heating cost comparison puts boilers and heat pumps beside it.

Typical values

Heater Typical power Heat per kWh of input
Oil-filled radiator 1–2.5 kW 1 kWh
Fan heater 2–3 kW 1 kWh
Convector / panel heater 1–2.5 kW 1 kWh
Infrared / halogen 0.4–2 kW 1 kWh (heats people, not air)
Split heat pump (heating) 0.5–1.5 kW input 2.5–4 kWh
LPG cabinet heater 1.5–4.2 kW 1 kWh of gas
Kerosene heater 2–3 kW 1 kWh of fuel

Ways to spend less

  • Heat the room you occupy and let the rest stay cool; that is where a small heater can come out ahead of whole-house heating.
  • Use the thermostat and a timer. Leaving it burning in an empty room wastes the most.
  • Keep the door shut and seal gaps, so the unit only covers the losses of one space.
  • Consider infrared at a desk or in a draughty workshop, where a few hundred watts pointed at you beats heating the air.
  • Look into a heat pump if one room is in use most of the winter: the split unit’s running cost is about a third. The heat pump calculator covers a whole house, and the air conditioner cost calculator deals with sizing.

Limits

A single average duty cycle replaces real behaviour, which shifts with outdoor temperature, insulation and thermostat setting. Room need is a rough W/m² rule assuming about −5 °C outdoors and a 2.5 m ceiling, a sanity check and not a heat-loss calculation. In severe cold a heat pump’s COP falls. LPG and kerosene prices vary a lot, with bottled kerosene far above bulk heating oil.

Method & assumptions

At full power, hourly cost = input kW × price per kWh. For LPG divide the price by 12.8 kWh/kg, and for kerosene by 9.6 kWh/L. Multiply by the duty cycle for the real hourly cost. The cost of a day is hourly cost × hours, and a winter is the daily cost × days. Heat delivered = input × COP, with COP 1 for resistance and flame heaters. The room's requirement is area × W/m² for its insulation level.

Frequently asked questions

What does an electric heater cost per hour?
Power in kilowatts times your tariff gives the answer. At €0.28/kWh a 1.5 kW unit runs up €0.42 each hour at full output and a 2 kW fan heater €0.56. Thermostats switch the element off once the room is warm, so in practice you will often pay only 50–70% of those figures.
Which electric heater is the cheapest to run?
Among resistance heaters, none is cheaper than another. Oil-filled, fan, convector, ceramic and infrared units all convert every kWh they draw into a kWh of heat, so the cost per unit of warmth is the same; only controls and the way the heat reaches you vary. The exception is a heat pump (a split air conditioner running in heating mode), which returns 2.5–4 times its electricity input as heat.
Is an oil-filled radiator a cheaper option than a fan heater?
Per unit of heat, no. A radiator feels milder, keeps giving off warmth after the element switches off, and usually has a smaller rating. It therefore draws less per hour and also delivers less. To hold the same room temperature over the same period, the electricity consumed ends up close.
What heater rating should I pick for a given room?
Plan for roughly 45 W per m² in a well-insulated room, 70 W/m² in a typical one and 100 W/m² in an old, leaky room during cold weather. Take a 16 m² room of average quality: it needs about 1.1 kW.
Does a portable heater beat central heating on cost?
It can, when you warm one room for a few hours and leave the rest of the house cold. Compare per kWh of heat and the picture changes: resistance heating usually runs two to three times dearer than a gas boiler and about three times dearer than a heat pump.
Can I use an LPG or kerosene heater inside a room?
Only with ventilation, since they emit water vapour, carbon dioxide and nitrogen dioxide into the room. Many countries forbid unflued models in bedrooms and bathrooms. Pair any such heater with a carbon monoxide alarm that works, and keep a window slightly open.

Sources & references

  1. US DOE Energy Saver: Portable Heaters
  2. US DOE Energy Saver: Electric Resistance Heating
  3. US EPA: Nitrogen Dioxide's Impact on Indoor Air Quality

Embed this calculator

Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.