Combined-cycle gas turbine (CCGT)
A plant in which a gas turbine's hot exhaust makes steam for a second, steam turbine, giving electrical efficiencies of 55–64%.
A CCGT joins a Brayton cycle (the gas turbine) to a Rankine cycle (the steam turbine). Exhaust leaves the gas turbine at 550–650°C and enters a heat recovery steam generator (HRSG), which makes steam at up to three pressure levels.
Take a gas turbine of 40% efficiency and a bottoming cycle of 35%: the combination reaches about 61% (LHV). The newest H- and J-class machines pass 63–64% LHV as combined cycles, while older plants run at 48–55%. A heat rate of 6,000–6,500 kJ/kWh matches such efficiencies and means direct emissions of roughly 330–370 g CO2/kWh, versus 820–1,000 g for coal.
Typical parameters (NREL ATB, Lazard 2024–2025): units of 250–1,000 MW; overnight capex about USD 900–1,500/kW, climbing since 2023 on turbine backlogs; a hot start takes 30–60 minutes and a cold one several hours; minimum stable load is around 40–50%. LCOE depends strongly on fuel and carbon price and generally falls at USD 45–110/MWh. Today CCGTs can burn hydrogen blends of 10–30% by volume, designs for 100% hydrogen have been announced, and CCS can be retrofitted.
Related terms
All terms →- Open-cycle gas turbine (OCGT)
A simple-cycle gas turbine venting hot exhaust straight to the air: efficiency is low (33–42%), but it starts quickly and costs little to build, so it mostly serves peaks.
- Natural gas
A fossil fuel made up mostly of methane, burned for electricity and for industrial and home heat, and used as a feedstock for hydrogen and ammonia.
- Heat rate
Fuel energy a thermal plant has to burn per kWh of electricity delivered; it is efficiency turned upside down, typically stated in BTU/kWh or kJ/kWh.
- CHP (Combined Heat and Power)
Producing electricity and usable heat together from a single fuel input, reaching 75–90% total efficiency, compared with about 35–60% for power-only plants.
- Carbon capture and storage (CCS)
Set of techniques that separate CO2 from exhaust or process gas, compress it, and pump it into deep rock formations for long-term storage.
- Load following
Raising or lowering a power plant's output over minutes to hours so it follows electricity demand or the swings of variable renewable generation.