Only coal beat gas in 2025: gas stations produced about 6,900 TWh, some 22% of the electricity used worldwide. In most power systems gas is the balancing fuel. Combined-cycle stations provide steady output, fast turbines and engines cover short peaks, and through much of the year the gas plant on the margin sets the market price. Each kWh brings roughly half the CO₂ that coal does, and construction is inexpensive. Against this stand fuel prices that jump around, reliance on imports in many countries, and methane lost on the way from well to burner.
Mechanics: three plant types
Methane (CH₄) makes up typically 85–95% of pipeline gas; the balance is ethane, propane, nitrogen and CO₂.
Open-cycle turbine (Brayton cycle). Compressors raise intake air to 15–25 times atmospheric pressure, about 30 in the newest designs. Gas burns in that air at flame temperatures above 1,500 °C in H- and J-class machines, and the expanding combustion gas turns a shaft that drives compressor and generator alike. The turbine exhaust is hot, roughly 450–650 °C.
Combined cycle. A combined-cycle gas turbine (CCGT) station captures that exhaust heat in a boiler-like heat recovery steam generator. Steam from it spins a second machine (Rankine cycle), lifting electricity output about 50% with no additional fuel. Common arrangements are “1×1” (one gas turbine, one steam turbine) and “2×1” (two gas turbines sharing a steam turbine).
Piston engines. Each unit produces 5–20 MW. Wärtsilä, MAN and Jenbacher are well-known makers, and stations of tens to hundreds of megawatts are built from many engines. They reach full output in under five minutes and lose little efficiency at partial load, which suits islands, mines and grids carrying a lot of variable renewables.
The yardstick for efficiency is heat rate: fuel energy put in per kWh sent out.
CO₂ intensity (kg/kWh) = heat rate (MMBtu/kWh) × emission factor (kg CO₂/MMBtu)
Example: CCGT at 6,500 Btu/kWh (HHV) = 0.0065 MMBtu/kWh; 0.0065 × 53.06 kg CO₂/MMBtu ≈ 0.345 kg CO₂/kWh
Two conventions exist, and mixing them misleads. The US reports higher heating value (HHV). Europe and equipment suppliers mostly quote lower heating value (LHV); gas’s LHV is about 90% of its HHV, so an identical plant seems roughly 10% more efficient in LHV terms. For conversions between cubic metres, therms, MMBtu and MWh of gas, try the fuel energy content calculator.
Main variants
| Technology | Net efficiency (LHV) | Heat rate (HHV, Btu/kWh) | Start-up to full load | Typical role |
|---|---|---|---|---|
| CCGT, H/J-class (new) | 60–64% | ~6,200–6,500 | 30–60 min (hot start) | Mid-merit / baseload |
| CCGT, US fleet average | ~50–55% | ~7,500 (EIA) | 1–3 h (cold) | Mid-merit / baseload |
| Aeroderivative OCGT | 38–44% | ~8,500–9,500 | 5–10 min | Peaking, reserves |
| Heavy-duty OCGT | 33–40% | ~9,500–11,000 | 10–30 min | Peaking |
| Reciprocating gas engines | 44–50% | ~8,000–8,800 | 2–5 min | Flexible peaking, islands |
| Gas steam boiler (legacy) | 30–38% | ~10,000–11,500 | hours | Being retired |
| Gas CHP | 75–90% total (power + heat) | n/a | varies | Industry, district heating |
H-class installations in Japan and France set the CCGT efficiency record, a shade over 63–64% LHV. Roughly 37% of the fuel still turns into low-temperature heat, and CHP stations sell it into district heating or to factories.
How often plants run
A gas station’s capacity factor depends on its job and on what gas costs. In the United States, combined-cycle plants averaged roughly 55–60% in recent years (EIA), and in some years inexpensive shale gas let them run more than coal plants. Open-cycle turbines mostly sit idle, at 5–15%, and start for demand spikes, plant outages or windless evenings. European CCGTs run less, with bigger swings: they gain when gas is cheaper than coal even after carbon costs, and lose when gas is pricey or wind and solar are strong. Convert hours to yearly output with the capacity factor calculator.
Few thermal technologies respond as fast. Modern CCGTs change load by 30–80 MW per minute; engines and aeroderivatives go from cold to running in minutes. That explains why gas provides a large share of peak load capacity, reserves and standby for wind and solar. Repeated cycling, however, raises maintenance bills and cuts efficiency.
Cost structure
Capital cost is low, operating cost high, the opposite of renewables and nuclear.
In the US, Lazard’s 2024 LCOE+ analysis (without subsidies) puts combined cycle at $45–108/MWh and peakers at $110–228/MWh. It assumes gas at a few dollars per MMBtu, with CCGTs running at 30–90% and peakers at 10–15% of the time. The IEA/NEA 2020 report lists a median of about $71/MWh at 7% discount rate for CCGT, assuming a $30/t carbon price; regional gas prices make the range wide. For new CCGT capacity NREL ATB and EIA AEO give overnight capital of roughly $1,000–1,300/kW, a little less per kW for combustion turbines.
Gas itself is the main cost. A plant burning 6.5 MMBtu per MWh sees about $6.5/MWh for every $1/MMBtu on the gas price. Henry Hub prices of $2–4/MMBtu therefore translate to $13–26/MWh fuel cost. When monthly TTF averages in Europe briefly passed €200/MWh in 2022 (about $60/MMBtu), the fuel alone cost around €350 for each MWh of electricity. Add a carbon price of €80/t and a CCGT pays another €28–32/MWh. The LCOE calculator lets you try other inputs. Set the capacity factor to 10% to see how a cheap-to-build peaker becomes costly per MWh.
Imported LNG
Where pipelines do not reach, countries buy liquefied natural gas, which is chilled to about −162 °C and shipped. The chain of liquefaction, shipping and regasification consumes some 10–15% of the energy and adds several dollars per MMBtu. Depending on the route it also raises lifecycle emissions by 10–40%. In 2023 the US took over from Qatar and Australia as top LNG exporter. Gas markets that were regional are now partly one market, so cold weather in Asia can send European power prices up.
Land and cooling water
Power stations occupy little land, often only a few hectares even for a gigawatt-scale CCGT; wells, gathering lines and pipelines upstream take much more, notably in shale basins. For each MWh a CCGT uses about a third of the cooling water of coal or nuclear plants, because the gas turbine’s heat leaves in the exhaust. Macknick et al. (NREL, 2012) found medians of about 200 US gallons per MWh for tower-cooled CCGTs, against roughly 700 for coal and nuclear. With air-cooled condensers consumption can approach zero, at a slight efficiency cost. Open-cycle turbines hardly use water at all.
Emissions over the whole chain
Counting only the stack understates the total. Leaks along wells, compressors, pipelines and LNG plants (methane leakage) matter because methane’s global warming potential is about 30 over 100 years and about 80 over 20 years (IPCC AR6).
For combined cycle the IPCC AR5 WGIII Annex III (2014) reports a median of 490 gCO2e/kWh (range 410–650), and UNECE 2021 gives 403–513 gCO2e/kWh for NGCC without capture. With CCS UNECE finds roughly 90–220 gCO2e/kWh, held back by capture rates and upstream methane. Because of their lower efficiency, open-cycle turbines emit 50–60% more per kWh than CCGTs.
Nobody knows the true leak rate. Alvarez et al. (Science, 2018) measured US supply-chain emissions of about 2.3% of gross gas production, around 60% higher than the EPA inventory. The IEA Global Methane Tracker estimates that about 40% of methane from oil and gas could be avoided at no net cost. The 20-year point where gas stops beating coal falls, according to lifecycle studies, at leakage of a few percent. On a 100-year horizon gas stays well ahead for most plausible leakage values. Satellites that spot super-emitters, programmes for finding and fixing leaks and the EU methane regulation (imports included) all aim at that gap.
Health record and hazards
Combustion of gas releases hardly any sulfur dioxide, particulates or mercury. Nitrogen oxides remain, and dry low-NOx burners and selective catalytic reduction keep them in check. Per unit of energy, gas harms health far less than coal or oil. For European gas, Markandya & Wilkinson (Lancet, 2007) estimated about 4 deaths per TWh. Our World in Data’s synthesis arrives at about 2.8 deaths per TWh, compared with about 24.6 for coal and 0.03 for nuclear, wind and solar. Hazards along the supply chain include pipeline explosions, well blowouts, storage accidents such as Aliso Canyon (California, 2015–2016) and local air and water effects near shale operations.
Decarbonisation options
Carbon capture. Gas exhaust holds little CO₂ (about 4%, versus 12–14% for coal), so amine capture after combustion costs a CCGT more effort than a coal unit: 7–10 percentage points of efficiency. The UK Net Zero Teesside Power project (about 740 MW; investment decision in late 2024) should become the first commercial-scale gas station with CCS, with capture of up to 95%.
Hydrogen blending. New turbines mostly tolerate 30–50% hydrogen by volume, with 100% targeted by manufacturers around 2030. Per cubic metre hydrogen carries about one-third of methane’s energy, so even a 30% blend lowers CO₂ by about 10%. The hydrogen also has to come from a low-carbon source. See the green hydrogen calculator for the electricity needed and green hydrogen for costs.
Biomethane produced by anaerobic digestion substitutes for fossil gas one-to-one, but available volumes fall far short of what power generation would need.
Outlook
The picture varies by region. Between 2008 and 2024 US shale gas replaced coal, and gas now makes roughly 40% of US electricity. Orders for new turbines have returned with data-centre demand, and delivery times for heavy-duty units stretched to several years by 2025. In Europe the 2022 price shock sped up renewables and efficiency, so less gas is burned for power; still, gas covers dark, windless periods and gets paid through capacity markets. Large CCGT fleets are still being added in the Middle East, Southeast Asia and parts of Africa.
Under net zero, gas stations would sell capacity rather than energy. They would run few hours as firm backup alongside battery storage and wind power, eventually burning hydrogen or biomethane or using CCS. Use the world energy map to see which countries lean on gas most, and the technology comparison to put its cost and emissions next to the alternatives.
Frequently asked questions
What efficiency does a gas-fired power station reach?
CCGT versus OCGT: what separates them?
What are the CO2 emissions of gas power per kWh?
Does gas beat coal on climate?
What drove the 2022 jump in gas-fired power prices?
Is it possible to burn hydrogen in gas turbines?
Sources & references
- EIA — Electric Power Annual, average heat rates by prime mover and energy source
- Lazard — Levelized Cost of Energy+ (2024)
- IEA/NEA — Projected Costs of Generating Electricity 2020
- UNECE (2021) — Life Cycle Assessment of Electricity Generation Options
- Alvarez et al. (2018) — Assessment of methane emissions from the U.S. oil and gas supply chain, Science 361
- IEA — Global Methane Tracker
- Electricity statistics by Ember and the Energy Institute, supplied through Our World in Data and used for this page's charts and tables