Glossary · Solar

NOCT

Nominal Operating Cell Temperature: how hot PV cells get when sunlight is 800 W/m², the air is 20 °C and wind is 1 m/s, on an open rack.

Where STC is a lab rating, NOCT tells you how warm a module gets under more realistic sun. It is defined by 800 W/m² irradiance, 20 °C ambient, 1 m/s wind, an open-circuit module and open-back mounting at 45° tilt. IEC 61215:2016 replaced it with NMOT (Nominal Module Operating Temperature), taken with the module delivering maximum power; NMOT comes out 1–3 °C lower.

Glass-backsheet modules usually show 41–46 °C, and some glass-glass types a bit more. A datasheet often adds power at NOCT, normally 74–76% of the STC value.

Tcell ≈ Tamb + (NOCT − 20 °C) / 800 W/m² × G

Example: NOCT 45 °C, ambient 30 °C and G = 1,000 W/m² yield Tcell of about 61 °C. Combine that with the power temperature coefficient to estimate the derating from heat.

Keep in mind that the formula presumes an open rack. Mounting and wind change real temperatures a great deal. Flush roof installations can be 10–20 °C hotter, and floating or very windy sites cooler. Simulation software accordingly uses finer thermal models (Faiman, Sandia, PVsyst U-value model) tuned for each mounting type.

Related terms

All terms →
  • Temperature coefficient

    How much a PV module's power, voltage or current changes, in percent, for each degree Celsius its cells sit above or below 25 °C.

  • Standard Test Conditions (STC)

    Standard test conditions for rating PV modules: 1,000 W/m² of irradiance, a 25 °C cell temperature, and the AM1.5G spectrum of sunlight.

  • Performance ratio

    Actual AC energy delivered divided by the theoretical output given plane-of-array irradiation and nameplate capacity; a quality measure for PV plants that does not depend on location.

  • Floating solar

    Solar arrays on buoyant platforms floating on reservoirs, lakes, ponds or sheltered coastal water instead of occupying ground or roofs.