How much a PV module's power, voltage or current changes, in percent, for each degree Celsius its cells sit above or below 25 °C.

A hot solar cell converts less light into power. The reason is mostly physical: the bandgap shrinks and open-circuit voltage falls. Datasheets give three coefficients. γ applies to maximum power and is the figure to watch; β applies to open-circuit voltage; α applies to short-circuit current and is slightly positive.

P = PSTC · [1 + γ · (Tcell − 25 °C)]     Tcell ≈ Tamb + (NOCT − 20) / 800 · G

Power coefficients γ across cell types, from best to worst:

  • Heterojunction: −0.24 to −0.26 %/°C
  • CdTe thin film: −0.28 to −0.32 %/°C
  • TOPCon: −0.29 to −0.32 %/°C
  • PERC monocrystalline: −0.34 to −0.37 %/°C
  • Multicrystalline silicon: −0.39 to −0.42 %/°C

An example calculation. Ambient 35 °C, sunshine 1,000 W/m², NOCT 44 °C: cell temperature is about 65 °C. A module with γ = −0.35 %/°C then falls 14% short of its STC rating, and an HJT module at −0.25 %/°C falls 10% short. Averaged over the year, the loss to heat is typically 2–4% in temperate zones and 6–10% in hot deserts.

The mounting method is nearly as important as the cell type: with no ventilation at the back, roof-integrated modules may run 15–20 °C warmer than the same panels on an open ground rack. Voltage coefficients are also used to choose string length against the lowest expected temperature.

Related terms

All terms →
  • NOCT

    Nominal Operating Cell Temperature: how hot PV cells get when sunlight is 800 W/m², the air is 20 °C and wind is 1 m/s, on an open rack.

  • Standard Test Conditions (STC)

    Standard test conditions for rating PV modules: 1,000 W/m² of irradiance, a 25 °C cell temperature, and the AM1.5G spectrum of sunlight.

  • Heterojunction (HJT) solar cell

    Solar cell design in which a thin amorphous silicon coating sits on both faces of an n-type crystalline silicon wafer, producing high voltage and little loss when hot.

  • Performance ratio

    Actual AC energy delivered divided by the theoretical output given plane-of-array irradiation and nameplate capacity; a quality measure for PV plants that does not depend on location.

  • String (PV)

    A series connection of PV modules, in which the voltages are added and the current equals that of one module.