How much a PV module's power, voltage or current changes, in percent, for each degree Celsius its cells sit above or below 25 °C.
A hot solar cell converts less light into power. The reason is mostly physical: the bandgap shrinks and open-circuit voltage falls. Datasheets give three coefficients. γ applies to maximum power and is the figure to watch; β applies to open-circuit voltage; α applies to short-circuit current and is slightly positive.
Power coefficients γ across cell types, from best to worst:
- Heterojunction: −0.24 to −0.26 %/°C
- CdTe thin film: −0.28 to −0.32 %/°C
- TOPCon: −0.29 to −0.32 %/°C
- PERC monocrystalline: −0.34 to −0.37 %/°C
- Multicrystalline silicon: −0.39 to −0.42 %/°C
An example calculation. Ambient 35 °C, sunshine 1,000 W/m², NOCT 44 °C: cell temperature is about 65 °C. A module with γ = −0.35 %/°C then falls 14% short of its STC rating, and an HJT module at −0.25 %/°C falls 10% short. Averaged over the year, the loss to heat is typically 2–4% in temperate zones and 6–10% in hot deserts.
The mounting method is nearly as important as the cell type: with no ventilation at the back, roof-integrated modules may run 15–20 °C warmer than the same panels on an open ground rack. Voltage coefficients are also used to choose string length against the lowest expected temperature.
Related terms
All terms →- NOCT
Nominal Operating Cell Temperature: how hot PV cells get when sunlight is 800 W/m², the air is 20 °C and wind is 1 m/s, on an open rack.
- Standard Test Conditions (STC)
Standard test conditions for rating PV modules: 1,000 W/m² of irradiance, a 25 °C cell temperature, and the AM1.5G spectrum of sunlight.
- Heterojunction (HJT) solar cell
Solar cell design in which a thin amorphous silicon coating sits on both faces of an n-type crystalline silicon wafer, producing high voltage and little loss when hot.
- Performance ratio
Actual AC energy delivered divided by the theoretical output given plane-of-array irradiation and nameplate capacity; a quality measure for PV plants that does not depend on location.
- String (PV)