Glossary · Wind

Wake effect

The region of slower, more turbulent air behind a wind turbine, which reduces the output of turbines downwind and adds to their fatigue loads.

Extracting energy from the wind leaves a wake: air that is slower and more turbulent. Directly behind the rotor the speed can be 30–50% below the free stream. Mixing with the surrounding air restores it, but only over many rotor diameters (D). Power varies with wind speed cubed, which means a 10% speed deficit takes roughly 27% off the output of the next turbine in line.

Designers commonly space turbines 5–9 D apart along the prevailing wind and 3–5 D across it. Typical annual energy lost to wakes across the array:

  • Onshore farms: 5–12%
  • Big offshore arrays: 10–20%; at Horns Rev and Lillgrund, measurements found individual rows down 30–40% when the wind lined up with them

Over water, wakes linger. The sea is smooth and the air often stable, so less mixing occurs. German Bight studies and satellite SAR images show wakes from whole clusters extending 30–60 km. A farm can therefore take yield from a neighbour, which now features in North Sea lease planning.

Models used in practice are Jensen/Park (a top-hat deficit), the Bastankhah-Porté-Agel Gaussian family and NREL's FLORIS framework; complex cases go to large-eddy simulation. With wake steering, the yaw system of upwind turbines is set a few degrees off the wind, and field trials saw farm output increase 1–3%.

Related terms

All terms →
  • Offshore wind

    Wind turbines standing in the sea or a large lake, mostly on fixed foundations in water as deep as about 60 m, where winds blow harder and more evenly than on land.

  • Power curve

    How a turbine's electrical output depends on wind speed at hub height; with a wind speed distribution it yields an estimate of yearly energy production.

  • Yaw system

    The slewing ring, drives, gears and brakes that turn a wind turbine nacelle around the tower axis so the rotor keeps facing the wind.

  • Repowering

    Replacing worn-out generating equipment at an existing site with newer machines that are generally bigger and more efficient. Wind farms are the usual case, after 15 to 25 years.

  • Capacity factor

    Actual energy a power plant generates in a period divided by what it would generate at full nameplate capacity throughout that period.