Coal guide

Coal Grades and Coal Power Plant Operation

Coal rank from lignite to anthracite, steam versus coking coal, and how a coal plant turns fuel into power: boilers, efficiency, heat rate, filters.

Updated 6 min read 1,494 words

Ember’s Global Electricity Review 2025 credits coal with about 34% of world electricity in 2024, roughly 10,600 TWh, still the largest single source. Yet “coal” covers very different materials, from glossy, hard anthracite to crumbly brown lignite that is half water, and it is burned in plant designs honed for over a century. Here you will learn what coal is, how grades differ and what takes place between the stockpile and the transmission line. Closures and new builds are covered separately in Coal Phase-Out Around the World.

Where grades come from

Coal began as plant material buried in swamps and then pressed and heated for millions of years. Heat and pressure steadily expel water, oxygen and volatile compounds, leaving a higher proportion of carbon. Geologists call the degree of this change rank. Young, wet coal is low rank; old, dense, energy-rich coal is high rank.

Typical properties by rank (carbon content, moisture as mined, energy as received, main uses):

  • Lignite (brown coal): 25–35% carbon, 30–60% moisture, 8–15 MJ/kg. Burned in mine-mouth power plants.
  • Sub-bituminous: 35–45% carbon, 15–30% moisture, 18–24 MJ/kg. Used for power generation.
  • Bituminous: 45–86% carbon, 2–15% moisture, 24–32 MJ/kg. Used for power and cement, and it includes coking coal.
  • Anthracite: 86–97% carbon, under 15% moisture, 26–33 MJ/kg. Used for heating and specialist industry.

These ranges follow the U.S. EIA and common industry classes, and single seams vary a lot. Ash, the mineral residue that will not burn, and sulphur count as much as rank. Consider Indonesian sub-bituminous coal, the mainstay of Asia’s power stations. Its energy is modest, often 4,200–5,000 kcal/kg (about 17.5–21 MJ/kg), but buyers like its low ash and sulphur. Australian export thermal coal typically carries close to 6,000 kcal/kg (about 25 MJ/kg). The fuel energy content calculator compares these with oil, gas and wood.

Steam coal and coking coal

Most coal is thermal coal, bought for its heat. Contract prices are corrected for calorific value, ash and moisture. Newcastle in Australia (6,000 kcal/kg) and Richards Bay in South Africa set the main seaborne benchmarks; Chinese and Indonesian indices price the lower grades. Prices are tracked on our coal prices page.

Metallurgical (coking) coal belongs to a special family of bituminous coals. Heated without air in a coke oven, they soften, swell and fuse into coke, a hard, porous carbon that reduces iron ore and also supports the load inside a blast furnace. The market is far smaller, around a tenth of world output, but substitutes are scarce. About 70% of the world’s steel comes from blast furnaces, which worldsteel says use close to 770 kg of coal per tonne of steel.

World coal production hit a record of about 9 billion tonnes in 2024, the IEA’s Coal 2024 report states. China supplied half; India, Indonesia, the United States, Australia and Russia followed.

A pulverised coal plant, step by step

Nearly all large coal units are pulverised coal (PC) plants, and the process runs along a single line:

  1. Handling. Coal comes in by train, conveyor or ship and goes onto stockpiles. A 1,000 MW plant normally holds several weeks of fuel.
  2. Milling. Mills grind it finer than flour, mostly under 75 microns, so that it burns almost at once.
  3. Boiler. Blown in with hot air, the powder burns in the furnace at about 1,300–1,500 °C. Steel tubing thousands of metres long lines the walls, soaking up heat and boiling high-pressure water into steam.
  4. Turbine. Steam expands across high-, intermediate- and low-pressure stages, spinning the turbine at 3,000 rpm on 50 Hz grids and 3,600 rpm on 60 Hz ones.
  5. Generator. A generator on the same shaft produces power at around 20–25 kV, and a step-up transformer lifts it to transmission voltage.
  6. Condenser and cooling. A condenser, cooled by river, sea or cooling-tower water, turns used steam back into water, which pumps feed to the boiler again.

Before it rises up the chimney, the flue gas passes through pollution controls. A minority of plants rely on circulating fluidised bed (CFB) boilers. These burn crushed coal at lower temperatures, suspended in a bed of hot sand and limestone, and they cope with poor-quality coal, biomass and waste fuels while trapping sulphur in the furnace itself.

Subcritical, supercritical and ultra-supercritical

Hotter, higher-pressure steam lets the turbine turn more of the fuel’s heat into work. Above 22.1 MPa, the critical point of water, there is no distinct boiling phase, which makes “once-through” boilers with hotter steam possible.

  • Subcritical: 16–18 MPa, ~540 °C, net efficiency (LHV) 33–37%, about 920–1,000 g CO₂/kWh from hard coal.
  • Supercritical: 23–25 MPa, 540–580 °C, 38–42%, about 800–880 g.
  • Ultra-supercritical (USC): 25–30 MPa, 580–620 °C, 42–47%, about 720–800 g.
  • Advanced USC (R&D): 30–35 MPa, 700 °C+, ~48–50% targeted, about 670 g.

Typical ranges come from IEA and manufacturer data. The largest USC fleet is China’s, where the best units report net efficiency near 46–48%. Indian plants are younger than European ones yet mostly subcritical, in part because Indian coal carries so much ash (often 30–45%).

Heat rate

Operators tend to talk about heat rate, meaning the fuel energy needed per kWh generated, rather than efficiency. It is efficiency inverted; the heat rate glossary entry explains the unit conventions.

Heat rate (kJ/kWh) = 3,600 ÷ efficiency Heat rate (Btu/kWh) = 3,412 ÷ efficiency

Example: a 1,000 MW supercritical unit at 40% efficiency Heat rate = 3,600 ÷ 0.40 = 9,000 kJ/kWh Coal use at full load (25 MJ/kg coal) = 1,000,000 kWh × 9,000 kJ/kWh ÷ 25,000 kJ/kg ≈ 360,000 kg/h ≈ 360 t/h ≈ 8,640 t/day CO₂ per kWh of electricity = 0.34 kg CO₂ per kWh of fuel (hard coal) ÷ 0.40 ≈ 0.85 kg CO₂/kWh

A single extra percentage point of efficiency on a large unit saves roughly 2.5% of fuel and CO₂. That explains why operators pay for turbine upgrades, cleaner boiler tubes and better condenser vacuum. You can try your own figures in the electricity CO₂ calculator.

Cleaning the exhaust

Coal combustion emits far more than CO₂, so modern plants chain several cleaning stages:

  • Electrostatic precipitators (ESPs) or fabric filters capture fly ash by charge or by fabric, removing over 99% of dust by mass.
  • Flue gas desulphurisation (FGD) scrubs sulphur dioxide, typically with wet limestone, at 90–98% removal, and yields gypsum that plasterboard makers can use.
  • Selective catalytic reduction (SCR) sends ammonia across a catalyst, which converts 80–90% of nitrogen oxides into nitrogen and water, with low-NOx burners upstream doing part of the job.
  • Activated carbon injection captures mercury where rules demand it, for example in the US under MATS.

The equipment is expensive and takes a few percent of the plant’s output, so plenty of older plants in lower-income countries run without the full set. CO₂ is untouched by all of them; removing it needs a separate post-combustion unit, described in Carbon Capture and Storage Explained. The ash left over is either sold into cement and concrete or kept in ponds and landfills.

Coal power today

China and India alone accounted for about two-thirds of coal-fired electricity worldwide in 2024. Ember reports that coal provided roughly 58% of China’s power and around 75% of India’s. Both are installing record solar and wind capacity, yet demand growth keeps coal output close to its peak.

Southeast Asia was the fastest-growing coal region over the past decade. Malaysia brings in almost all of its coal, mainly from Indonesia, Australia and Russia. A few big coastal plants in Peninsular Malaysia burn it:

  • Manjung (Janamanjung), Perak: ~4,100 MW, five units, including two newer ~1,000 MW supercritical/USC units.
  • Jimah and Jimah East, Negeri Sembilan: ~3,400 MW; Jimah East has two 1,000 MW ultra-supercritical units.
  • Tanjung Bin, Johor: ~3,100 MW, including a 1,000 MW supercritical unit.
  • Kapar, Selangor: ~1,500 MW of coal units, an older multi-fuel station.

Capacities are approximate, rounded from operator disclosures. Ember has coal at around 40% or more of Malaysian generation in recent years. Under the National Energy Transition Roadmap no new coal plants will be built, and the existing fleet retires gradually by about 2044. More detail: how Malaysia’s electricity works, the Malaysia electricity hub and the Malaysia country profile.

Key points

  • Buyers pay for energy, ash and sulphur, not just tonnes. Lignite holds only about a third as much energy per kilogram as good bituminous coal.
  • Plant efficiency ranges from 33% to about 47%, and each point saved cuts fuel use and CO₂ by about 2.5%.
  • Modern controls deal well with dust, SO₂ and NOx. CO₂ requires dedicated capture equipment, which few plants have.
  • China, India, Indonesia and much of Southeast Asia still run largely on coal; Europe and North America are cutting it quickly.

Country-level data sits on the coal energy hub, the coal technology page and the global power plants map.

Calculators related to this topic

Frequently asked questions

Thermal coal versus coking coal: how do they differ?
Power plants and cement kilns burn steam (thermal) coal purely for heat, so the price follows energy content. Coking (metallurgical) coal is a low-ash, low-sulphur bituminous grade. On heating it softens, then sets into coke, which is strong enough to bear the weight of the charge in a blast furnace. Supply is tighter and the price usually higher.
What is the efficiency of a coal-fired power station?
On a lower-heating-value basis, subcritical units of older design turn roughly 33–37% of the fuel's energy into power. Supercritical plants manage about 38–42%, and the best ultra-supercritical ones 44–47%. The balance is lost as heat to cooling water and flue gas.
What are the CO₂ emissions of coal-fired electricity?
Efficiency sets the figure: hard coal typically gives 750–1,000 g CO₂ per kWh, lignite 950–1,200 g. A modern combined-cycle gas plant emits a third to a half as much.
Why is the energy content of lignite so low?
Lignite is geologically young and still contains 30–60% water and less fixed carbon. A large part of its heat is used up evaporating that moisture, leaving roughly 8–15 MJ/kg as mined, compared with 24–30 MJ/kg for good bituminous coal. Being wet and heavy, it cannot be shipped far, so lignite plants stand beside the mine.
Is coal still used for electricity in Malaysia?
Yes. Peninsular Malaysia gets a big share of its power from imported-coal stations (Manjung, Jimah, Tanjung Bin, Kapar), and Ember has coal at around 40% or more of national generation lately. Official policy is no new plants and a phase-out by about 2044.
How much coal does a 1,000 MW power plant use?
Take a 1,000 MW plant at full load, 40% efficiency and 25 MJ/kg coal: that is about 360 tonnes an hour, around 8,600 a day. Over a year at a 60% capacity factor the total approaches 1.9 million tonnes.

Sources & references

  1. Ember — Global Electricity Review 2025
  2. IEA — Coal 2024: Analysis and forecast to 2027
  3. U.S. EIA — Coal explained: types of coal
  4. worldsteel — Steel and raw materials fact sheet
  5. Energy Institute — Statistical Review of World Energy 2025

The figures in this guide are typical ranges taken from the listed sources, and your own values will vary with location, prices and equipment. For estimates specific to your site, use the linked calculators.