Fossil fuels · energy technology

Coal-Fired Power: Plants, Costs and Health Toll

Coal remains the number-one source of electricity, and the top contributor to energy-related CO₂ and air-pollution deaths as well.

World generation 2025
10,472TWh
≈ 1,272 kWh per person
Portion of global electricity
33.0%
out of 31,772 TWh generated in total
10-year change
+13%
2015–2025 · +1.2% a year
Countries generating
84
peak: 10,539 TWh in 2024

Global coal power output from 1985 onwards

World energy map →

Yearly electricity produced by coal power worldwide

Annual TWh, 1985–2025. Data: Ember and Energy Institute through Our World in Data (CC BY 4.0).

Leading countries

All rankings →

Top 15 by generation

TWh, latest year
#CountryTWhShare
1🇨🇳China5,75254.3%
2🇮🇳India1,47470.8%
3🇺🇸United States73716.3%
4🇯🇵Japan33032.1%
5🇮🇩Indonesia22861.5%
6🇷🇺Russia22018.4%
7🇿🇦South Africa19881.4%
8🇰🇷South Korea19531.1%
9🇻🇳Vietnam14948.1%
10🇦🇺Australia12242.7%
11🇹🇷Türkiye12134.3%
12🇹🇼Taiwan10536.3%
13🇩🇪Germany10320.6%
14🇲🇾Malaysia89.644.6%
15🇵🇱Poland87.350.4%

Fifteen leading countries by electricity share

limited to countries producing at least 5 TWh a year
#CountryShareTWh
1🇲🇳Mongolia85.8%8.31
2🇿🇦South Africa81.4%198
3🇮🇳India70.8%1,474
4🇷🇸Serbia65.0%23.8
5🇲🇦Morocco61.5%27.4
6🇮🇩Indonesia61.5%228
7🇵🇭Philippines58.7%72.2
8🇰🇭Cambodia56.6%10.1
9🇧🇦Bosnia and Herzegovina55.4%8.00
10🇨🇳China54.3%5,752
11🇰🇿Kazakhstan54.3%67.1
12🇵🇱Poland50.4%87.3
13🇻🇳Vietnam48.1%149
14🇲🇾Malaysia44.6%89.6
15🇿🇼Zimbabwe42.9%4.40

By continent

Output per continent, 2000–2024

TWh per year, stacked.
ContinentTWh 2024% of world% of its power
Asia8,86884.3%49.2%
North America7036.7%12.7%
Europe5305.0%11.4%
Africa2452.3%25.5%
Oceania1301.2%38.4%
South America42.30.4%3.2%

“% of its power” means the technology's portion of a continent's own electricity output. Continental totals come from Our World in Data and may differ a little from the global figure when added up.

Installed capacity recorded in the worldwide plant database

Power plant map →
#CountryCapacity (MW)% of listed
1🇨🇳China955,71848.7%
2🇺🇸United States249,14912.7%
3🇮🇳India204,91910.4%
4🇩🇪Germany47,7732.4%
5🇷🇺Russia46,0722.3%
6🇯🇵Japan41,5132.1%
7🇿🇦South Africa39,7942.0%
8🇰🇷South Korea33,1331.7%
9🇵🇱Poland30,9591.6%
10🇮🇩Indonesia29,3331.5%
11🇺🇦Ukraine26,5501.4%
12🇦🇺Australia25,5431.3%
13🇹🇷Türkiye17,7070.9%
14🇰🇿Kazakhstan15,8680.8%
15🇹🇼Taiwan14,1900.7%

WRI Global Power Plant Database v1.3 (plants of about 1 MW and up, data from 2019–2021). Listed in total: 1,964.1 GW across 73 countries. It suits geographic questions; for present-day capacity, turn to IRENA or national statistics.

Key characteristics

Compare all →
VariantCapacity factorCost $/MWhgCO₂e/kWhLand m²/MWhDeaths/TWhBuild (yrs)
Coal40–70%69–168820 (740–910)15 (incl. mining)24.64–6

Costs come from Lazard LCOE+ 2024 (v17), without subsidies, in USD/MWh. IPCC AR5 WGIII Annex III supplies the emissions (median, min–max). Death rates are Markandya & Wilkinson (2007) and Sovacool et al. (2016), reached via Our World in Data.

Coal remains the largest single electricity source on Earth. One third of the world’s power in 2025, about 10,500 TWh, came from coal, even as solar and wind close the gap. It also tops the list of energy-related CO₂ emitters at roughly 15 billion tonnes yearly, most of it from power stations. For paid-off plants beside their own mine, output is cheap and can be dispatched at will, and many regional economies depend on that. Yet per unit of electricity, coal is the deadliest option available, because of what comes out of the chimney.

The process

Think of a coal plant as a large kettle driving a turbine (the Rankine cycle). Mills reduce coal to powder, air blows it into the boiler, and it burns at about 1,300–1,700 °C. Water flowing through thousands of metres of tubing takes up the heat; the high-pressure steam spins the turbine and generator, then condenses and returns to the boiler. Raise steam temperature and pressure and efficiency rises. That single lever defines the plant classes below.

CO₂ per kWh depends on two things, efficiency and the fuel’s carbon content:

CO₂ per kWh = (3.6 MJ ÷ η) × EF
EF (IPCC 2006 defaults): bituminous coal ≈ 94.6 kg CO₂/GJ · sub-bituminous ≈ 96.1 · lignite ≈ 101
Example: hard coal unit at η = 38% → 3.6 ÷ 0.38 = 9.47 MJ/kWh × 0.0946 kg/MJ ≈ 0.90 kg CO₂/kWh
Same unit at η = 45% (USC) → 0.76 kg CO₂/kWh (−16%)

Fuel burn comes from the same arithmetic. With coal at 25 MJ/kg, a 38% unit needs 0.38 kg per kWh, so a 1 GW unit at full load gets through about 3.3 million tonnes yearly. Heating values for coal and other fuels sit side by side in the fuel energy content calculator.

Technology classes

Technology Steam conditions Net efficiency (LHV) CO₂ at stack, hard coal Notes
Subcritical PC <22 MPa, ~540 °C 32–38% ~0.90–1.05 kg/kWh Bulk of older fleets in US, India, Europe
Supercritical PC >22.1 MPa, ~565–585 °C 38–42% ~0.80–0.90 kg/kWh Standard for 1990s–2000s builds
Ultra-supercritical (USC) ~25–30 MPa, ≥600 °C 42–47% ~0.72–0.80 kg/kWh Japan, Germany, Korea, China
Advanced USC (R&D) ~35 MPa, ~700 °C 47–50% (target) ~0.68 kg/kWh Needs nickel superalloys
IGCC Gasification + combined cycle 38–45% ~0.75–0.85 kg/kWh Few plants; high cost
Circulating fluidised bed Sub- to supercritical 34–42% similar to PC Low-grade coal, co-firing biomass
  • Supercritical: beyond 22.1 MPa and 374 °C water no longer boils, it simply becomes steam. Once-through boilers are designed around that.
  • Ultra-supercritical: above 600 °C. Best plants (Japan, Denmark, China) report 44–47% net (LHV), paid for with costly high-alloy steel.
  • IGCC (integrated gasification combined cycle): coal becomes syngas, which is cleaned and burned in a gas turbine backed by a steam cycle. Capturing CO₂ before combustion gets easier. Buggenum (Netherlands), Puertollano (Spain), Polk, Wabash River and Edwardsport (US) were demonstrations with uneven availability. Mississippi’s Kemper County abandoned gasification in 2017 once costs hit about $7.5 billion; gas now fuels it.

Brown coal versus black coal

  • Lignite: about 5–15 MJ/kg, 30–60% moisture, uneconomic to transport. Burned beside the mine in Germany, Poland, Czech Republic, Greece, the Balkans, Türkiye, Victoria (Australia) and Indonesia.
  • Emissions: wasted drying energy plus a high carbon content give typically 1.0–1.2 kg CO₂/kWh. Its strip mines scar more land than almost any other energy supply chain.
  • Hard coal: bituminous, sub-bituminous and anthracite, roughly 20–32 MJ/kg, shipped by sea. Biggest sellers: Indonesia, Australia. Biggest buyers: China, India, Japan, Korea.

How hard plants actually run

The design brief was baseload operation with a capacity factor of 70–85%. Today many fleets sit well below: roughly 40–50% for US plants in recent years (EIA), squeezed by cheap gas and renewables, and near 50% in China, where building outran demand. Frequent ramping wears equipment, drops efficiency and raises emissions per kWh. Most units cannot go below 30–50% of rated output, though retrofits in Germany, Denmark and China reach lower. The capacity factor calculator converts these rates to annual energy.

Economics

  • Lazard LCOE+ 2024 (US, unsubsidised, new): $69–168/MWh. Wind, solar and gas undercut it, which is why US coal proposals are scarce.
  • IEA/NEA Projected Costs 2020: new OECD coal usually $75–120/MWh at a 7% discount rate. That includes a $30/t carbon price worth about $25–30/MWh. Chinese and Indian projects cost much less per kW.
  • NREL ATB / EIA AEO: new US pulverised coal about $3,500–4,500/kW overnight, much more with 90% capture.

Existing plants are judged on marginal cost (fuel, variable O&M, carbon). Take hard coal delivered at $100/t (about $4/GJ): fuel alone costs roughly $38/MWh. Carbon at €80/t adds around €70/MWh, and the EU ETS explains most of the halving of European coal generation since 2015. Analysts such as Carbon Tracker conclude that many operating coal plants now cost more to run than new renewables cost to build. Test the effect of fuel and carbon prices in the LCOE calculator.

Land, water and waste

  • Fuel: every year a 1 GW plant swallows about 3 million tonnes of hard coal, or 8–10 million tonnes of lignite.
  • Residues: hundreds of thousands of tonnes of ash, plus gypsum with scrubbers. Ash ponds have collapsed, for instance at Kingston, Tennessee in 2008.
  • Mining: Appalachian mountaintop removal and the lignite pits of Germany’s Rhineland and Lusatia removed entire landscapes and villages.
  • Water: Per NREL’s survey (Macknick et al., 2012), tower-cooled units consume a median of about 690 US gallons per MWh, and once-through systems withdraw far larger volumes. Siting in water-stressed India and northern China is constrained by this.

Life-cycle CO2

  • IPCC AR5 WGIII Annex III (2014): pulverised coal median 820 gCO2e/kWh, range 740–910.
  • UNECE 2021: about 750–1,100 gCO2e/kWh without capture, by coal type and region. Fitted with CCS, the range drops to about 150–470 gCO2e/kWh, as capture is incomplete and mine methane remains.

Methane from mines is a big, often overlooked part; the IEA’s Global Methane Tracker ranks coal mining alongside oil or gas operations as an emitter. For reference, gas combined cycle comes in near 490 g, and nuclear and wind near 10 g.

Health

Pollution spreads through the air. Burning coal emits fine particulates (PM2.5), sulfur dioxide, nitrogen oxides (precursors of secondary particles and ozone), mercury, arsenic and other trace metals. Cardiovascular and lung disease, stroke and cancer follow, sometimes hundreds of kilometres from the stack.

  • Markandya & Wilkinson (Lancet, 2007): about 24.5 deaths per TWh for European hard coal, 32.6 for lignite, with many more serious illnesses.
  • Our World in Data: about 24.6 deaths per TWh for coal; oil 18.4, gas 2.8, nuclear, wind and solar about 0.03.

Controls change the picture a lot. Flue-gas desulfurisation strips 90–98% of SO₂, selective catalytic reduction 80–90% of NOx, electrostatic precipitators and fabric filters over 99% of particulates, and activated carbon captures mercury. China’s “ultra-low emission” limits (about 10/35/50 mg/Nm³ for dust/SO₂/NOx), in force across most of its fleet since 2015, helped cut urban PM2.5 sharply. Plenty of Indian and Southeast Asian plants lack FGD, and India has delayed compliance again and again. Add mining accidents and black lung to the total.

Carbon capture

Two flagship plants show the potential and the trouble.

  • Boundary Dam 3 (SaskPower, Canada, 2014): retrofit of a 110–115 MW (net) unit, sized to catch about 1 Mt CO₂/yr (90%). It runs more reliably now but has mostly captured less than designed, and buyers use much of the gas for enhanced oil recovery.
  • Petra Nova (W.A. Parish, Texas, 2017): treated a 240 MW-equivalent slipstream, with a design rate near 1.4 Mt/yr, and sent the CO₂ to oil fields. Mothballed in 2020 as oil prices crashed, restarted in 2023 under new owners.

Solvent regeneration and compression use 20–30% of plant output. Together with capital cost, that lifts generation cost roughly 40–80%, so coal with CCS ends up dearer than most low-carbon options.

Retirements and outlook

Regions diverge. In Britain coal supplied about 40% of power in 2012; the share hit zero when Ratcliffe-on-Soar shut on 30 September 2024. From a 2007 high of about 2,000 TWh, US coal output has more than halved and now covers under 20% of demand. EU coal power has roughly halved since 2015, and Germany intends to exit by 2038 at the latest, with Spain, Italy and others earlier.

In Asia the share falls while total output still climbs. China generates over half of world coal power and approved about 100 GW of new capacity per year in 2022–2023 (CREA, Global Energy Monitor), though the new units are increasingly framed as renewable backup rather than baseload. India takes about three-quarters of its electricity from coal and plans additions to match demand. Looking at the late 2020s, the IEA’s Coal 2024 report expects a plateau in world demand, a Chinese decline cancelling out growth in India and Southeast Asia.

How quickly coal leaves depends on affordable substitutes (solar, wind, battery storage, natural gas), carbon prices, financing for early closure such as the JETP deals with South Africa, Indonesia and Vietnam, and support for mining regions. Browse what remains on the power plant map, or weigh costs and emissions in the technology comparison.

Frequently asked questions

What efficiency do coal plants reach?
It depends on steam conditions. Subcritical boilers convert 32-38% of the fuel's lower heating value into power, supercritical ones 38-42%, ultra-supercritical (USC) designs 42-47%. Gain one percentage point and CO2 per kWh falls 2-3%.
How much carbon dioxide does a kWh from coal release?
Stack emissions run 0.75-1.0 kg CO2/kWh for hard coal and 0.95-1.2 kg/kWh for lignite, the spread coming from plant efficiency. Add mining and transport and you get life-cycle values: IPCC AR5 gives pulverised coal a median of 820 gCO2e/kWh; UNECE 2021 gives a band of 750-1,100 g.
How many people does coal power kill?
The figure from Our World in Data is 24.6 deaths for every TWh generated. Nearly all come from breathing polluted air (fine particulates, SO2, NOx); the rest are mining accidents. By comparison nuclear, wind and solar are roughly 800 times safer. Lignite fares worse than hard coal in the Lancet 2007 study by Markandya & Wilkinson, which covered European plants.
Lignite or hard coal: what separates them?
Water and energy. Lignite (brown coal) is geologically young, holds 30-60% moisture and gives only about 5-15 MJ/kg, so it is mined in open pits and burned next door. Hard coal (bituminous, anthracite) delivers about 24-32 MJ/kg and travels the world by ship. Drying lignite in the furnace wastes heat, which is why its plants emit more CO2 per kWh.
Has carbon capture worked on coal plants?
Technically yes; commercially it has struggled. Canada's Boundary Dam 3 (SaskPower) began capturing CO2 in 2014 and has mostly stayed below its 90% design target. In Texas, Petra Nova stopped in 2020 and came back in 2023. Capture lifts generation cost roughly 40-80% and consumes 20-30% of what the plant produces.
Where are new coal plants still being built?
Mainly in two countries. China, which already generates over half of all coal power, kept licensing large volumes in 2022-2024, and India draws about three-quarters of its power from coal. Elsewhere the trend points down: Britain shut its last plant in 2024 and the US and EU keep closing units.

Sources & references

  1. IEA — Coal 2024: Analysis and forecast to 2027
  2. Global Energy Monitor — Global Coal Plant Tracker
  3. IPCC AR5 WGIII Annex III — Technology-specific Cost and Performance Parameters
  4. Markandya, A. & Wilkinson, P. (2007). Electricity generation and health. The Lancet 370(9591)
  5. Our World in Data — What are the safest and cleanest sources of energy?
  6. Lazard — Levelized Cost of Energy+ (2024)
  7. Electricity statistics by Ember and the Energy Institute, supplied through Our World in Data and used for this page's charts and tables