Ask a Copenhagen resident where the boiler is and you will probably get a shrug. Heat reaches the flat through street-level mains, produced by waste incinerators, biomass CHP stations, heat pumps the size of warehouses and, increasingly, giant insulated tanks. Stockholm, Helsinki, Reykjavik and a large share of northern China follow the same pattern. The IEA estimates that networks meet roughly 9% of the world’s heat demand in buildings, though in some countries they are simply the default. What follows covers the engineering, the fuel mix, the economics and the cooling twin that has taken root in Kuala Lumpur.
Look up any country on the heat dashboard, or read the short district heating glossary entry.
How a heat network is built
Three elements make up the system.
- Generation. Central plants warm the water. A big network draws on several of them and runs the cheapest first, in the same merit-order logic as an electricity grid.
- Pipework. Steel pipes with factory-fitted insulation lie roughly one metre below ground. One line carries hot water to customers (supply); another returns the cooled water (return). Large cities lay trunk mains of 500–1,000 mm, which branch into thinner distribution lines.
- Customer substations. Every connected building has its own meter and heat exchanger. The water from the network is kept apart from the building’s own radiators and taps, and heat simply passes across stainless steel plates.
The heat handed over is set by two things, the flow rate and the temperature gap between the two lines:
Example: 80 °C supply, 45 °C return, 2 kg/s flow Q = 2 × 4.19 × 35 ≈ 293 kW (enough for roughly 40–60 flats on a cold winter day)
Getting the water back cold pays off in several ways: every pipe gets more out of the same diameter, less heat leaks, and equipment such as heat pumps, condensing boilers and flue-gas condensers runs more efficiently. That explains why Danish utilities frequently penalise customers who return water that is too warm.
The five generations
| Gen. | Period | Medium and flow temperature | Usual fuel or source |
|---|---|---|---|
| 1G | 1880s–1930s | Steam, over 150 °C | Coal furnaces (the New York steam system goes back to 1882) |
| 2G | 1930s–1970s | Pressurised hot water, over 100 °C | CHP burning coal and oil; Soviet-era builds |
| 3G | 1970s–2000s | Water at 70–100 °C, pre-insulated pipes | CHP, waste burning, biomass |
| 4G | 2010s onward | Warm water, 50–70 °C | Large heat pumps, surplus heat, solar thermal, thermal stores |
| 5G | Emerging | Ambient loop of about 10–25 °C | Heat pumps in each building, exchanging heat and cold |
A cooler loop wastes less in the pipes and welcomes weaker heat. Water at 55 °C can come straight from a data centre, a sewage heat pump or a solar field; a 120 °C network would need an extra boost step first.
What feeds the network
The oldest big source is combined heat and power (CHP). Plants that only generate electricity throw away over half their fuel energy as low-grade heat; send it into a network and the same plant reaches 80–90% total efficiency. Newer additions try to avoid fossil fuel altogether.
- Burning waste. Non-recyclable household waste heats Danish and Swedish homes. Copenhagen’s Amager Bakke, topped by a ski slope, serves roughly 150,000 households.
- Big heat pumps. Machines of several tens of megawatts, using seawater, sewage or river water, are no longer unusual. Esbjerg, Denmark, switched on a seawater unit of about 70 MW in 2023, replacing a coal plant. Assuming a COP of 3, every MWh of power yields about 3 MWh of heat; other cases can be tried in the heat pump calculator.
- Deep geothermal. Almost all of Reykjavik’s heat comes from hot groundwater, and Paris, Munich and several Chinese cities pump from deep aquifers. More detail: Geothermal Energy Explained.
- Solar thermal. Dronninglund, Marstal and Vojens in Denmark have large collector fields feeding pit stores.
- Surplus industrial heat rejected by data centres, refineries, steelworks and fertiliser plants.
- Biomass, chiefly wood chips and pellets, in boilers and CHP units.
Heat storage
Keeping heat is much cheaper than keeping electricity. Steel tanks holding one to two days of demand are common. In Denmark, lined and insulated pit thermal energy storage of 60,000–200,000 m³ saves summer solar heat for the colder months, while Helsinki’s utility Helen has reused disused underground oil caverns as heat reservoirs. With a store in place, heat pumps and electric boilers can be switched on during cheap-power hours, and the network becomes a flexible load that helps balance the grid (see demand response explained).
Five national pictures
Denmark. Roughly 65% of households are on a network, almost all of them in Copenhagen. The 1979 Heat Supply Act made municipal heat planning compulsory. Most utilities belong to municipalities or consumers and work non-profit, and gas boilers are being phased out wherever a network exists. Most heat today comes from biomass, waste and heat pumps.
Sweden. Networks supply over half of home and commercial heating. Fossil fuel now provides only a few percent; the remainder is biomass, waste, waste heat and heat pumps.
Finland. District heat holds about 46% of the national market, and around 90% of Helsinki’s buildings use it. Coal is leaving the capital: Hanasaari closed in 2023, burning at Salmisaari stopped in 2024, and heat pumps, electric boilers, biomass and storage fill the gap.
China. The country’s northern networks are the biggest anywhere, and official statistics show well over 10 billion m² of floor space supplied. Coal is still dominant, and burning it for heat is a leading source of winter smog. Under a “clean heating” campaign begun in 2017, many small coal boilers have given way to gas, heat pumps and recovered power station heat.
Eastern Europe and Russia. Numerous Soviet-era networks operate at high temperatures, with big losses and little metering. Poland, the Baltic states and Ukraine run some of the larger ones, so modernising them is a major chance to save energy.
Leaks, tariffs and regulation
Heat escapes from pipes faster when the temperature gap is wide and slower when insulation is good and customers sit close together. Today’s networks lose about 10–15% of what they produce, while old 2G systems lose 20–30% or more. Customer density counts as well. A tower block needs much less pipe per MWh than a street of detached houses, so cities suit heat networks better than suburbs.
A building can be tied to just one network, which makes district heat a natural monopoly. Danish rules require sale at cost. In Sweden and Finland, competing heat pumps and negotiated pricing keep tariffs in check. British networks, which supply only 2–3% of heat, come under Ofgem regulation from 2026. You can set the options side by side in the heating cost comparison calculator.
Cooling networks for hot places
In the tropics, the pipes carry cold instead. Water is chilled to about 4–6 °C at a central plant, typically by large high-efficiency chillers backed by overnight ice or chilled-water storage, then sent to offices, malls and campuses. One large plant can outperform many small rooftop units, buy cheaper night-time power and clear roof space.
- Singapore: At Marina Bay, SP Group runs one of the largest underground cooling networks anywhere, covering the financial district and the Marina Bay Sands area.
- Malaysia: Gas District Cooling (GDC), part of Petronas, has served the KLCC precinct with chilled water and electricity since the late 1990s and operates comparable plants in Putrajaya and at KLIA. Gas turbines drive absorption chillers that use waste heat.
- Gulf states: Dubai, Abu Dhabi, Doha and Riyadh have big schemes, because cooling accounts for most of their peak power demand.
The demand side is explained in air conditioning and cooling energy.
Takeaways
- Insulated pipes link a handful of big sources with many buildings.
- Running at 50–70 °C or ambient temperature reduces losses and opens the door to heat pumps, waste heat and solar thermal.
- The Nordic countries show how far fossil fuel can be removed; China shows how big the systems get and how hard coal is to shake.
- Losses of 10–15% are typical for modern networks, and density favours cities.
- Warm regions use the cooling variant: Singapore, Kuala Lumpur, Putrajaya and the Gulf.
More to read: industrial heat explained, heat pumps explained and the world energy map.
Calculators related to this topic
Frequently asked questions
What does district heating mean?
Which countries rely most on district heating?
How much heat do the pipes lose?
Does district heat cost less than a gas boiler?
How does district cooling work?
What is a 5G district heating network?