Heating & gas calculator

What will a new condensing boiler save you?

Sets your existing gas, LPG or oil boiler against a new condensing model: fuel and money saved each year, payback and CO₂. Flow temperature is taken into account, since a condensing boiler working at 75–80 °C hardly condenses at all.

Editable share link Branded PDF report Free · no sign-up

Results

Raising efficiency from 78% to roughly 92%, with better controls, lowers fuel consumption by 20% and saves 365 € per year. Payback on the boiler takes 9.6 years, and after 15 years you are 2,820 € up.
Saving per year
€365
20% less fuel
Payback
9.6 years
Net gain over 15 years
€2,820
assuming fuel prices rise 2% a year
Fuel saved per year
3,655kWh
from 18,000 to 14,345 kWh
Old boiler efficiency
78%
New boiler efficiency
92%
at 55 °C flow
CO₂ saved per year
738kg
Useful heat (unchanged)
14,040kWh/yr
Cumulative net saving
Annual saving at each flow temperature
  • Condensing boilers pull extra heat out of the water vapour in the flue gas, but only if the returning water is colder than the dew point: about 55 °C with natural gas and 47–48 °C with oil. Many get installed and then run at a 75–80 °C flow, so they perform like a decent ordinary boiler.
  • The efficiencies are seasonal net figures of the kind seen in field trials, a few points under laboratory ratings. Before replacing anything, try lowering the flow temperature on a condensing boiler you already have, often to 50–55 °C. It costs nothing and can pay off.

Same heat, less fuel

Whichever boiler you own, the house needs the same heat; what differs is the fuel burned to produce it. Starting from yearly fuel use and the old boiler’s seasonal efficiency, the calculator derives the useful heat that actually reaches the rooms, and then works out the fuel a condensing boiler would use to supply exactly that.

New-boiler efficiency depends on fuel and on the flow temperature. A condensing boiler only reclaims the heat in flue-gas water vapour when the return water is cold enough to make it condense, about 55 °C or less with natural gas and 47–48 °C with oil. Run at 75–80 °C and little condensing happens, so higher flow temperatures get lower seasonal efficiencies in the tool. If you tick smart or weather-compensating controls, heat demand drops about 6%, within the usual 4–8% range.

Equations

Useful heat = fuel per year × energy per unit × old efficiency New fuel = useful heat × controls factor ÷ new efficiency ÷ energy per unit Controls factor = 0.94 with smart / weather compensation, else 1

New efficiency (gas) = 95 / 92 / 89 / 86% at 45 / 55 / 65 / 75 °C flow Saving = (old fuel − new fuel) × price Payback = installed cost ÷ first-year saving Net gain = Σ savings with yearly price growth − installed cost

Gas billed in kWh counts as 1 per unit; LPG is 7.1 kWh per litre and heating oil 10.0 kWh per litre.

Example with default inputs

Imagine a gas-heated home using 18,000 kWh a year in a 1990s–2000s non-condensing boiler (78% seasonal). A condensing replacement costs €3,500 installed and runs at a 55 °C flow with weather-compensating controls. Gas is €0.10/kWh and climbs 2% a year.

  • Heat delivered to the home: 18,000 × 0.78 = 14,040 kWh.
  • Gas the new boiler needs: 14,040 × 0.94 ÷ 0.92 ≈ 14,345 kWh.
  • Gas avoided: about 3,655 kWh per year (20%), which is €365 in the first year.
  • Simple payback: €3,500 ÷ €365 ≈ 9.6 years.
  • Across 15 years with 2% annual price growth, the net gain is about €2,820.
  • Emissions avoided: 3,655 × 0.202 ≈ 740 kg of CO₂ a year.

The flow-temperature chart makes the point: at 45 °C this boiler saves roughly €411 a year, while left at 75–80 °C it saves only about €265.

Using the numbers

  • Saving per year: year one, priced at current rates.
  • Payback: simple payback measured against the whole installed cost. If the boiler needs replacing regardless, use only the extra cost of the better model as the numerator.
  • Lifetime net gain allows for fuel price growth, but not discounting or changing maintenance.
  • Useful heat (unchanged) is what the home truly needs, the figure to carry into the sizing of a new boiler or heat pump.

Efficiency and emissions reference

Seasonal efficiency by boiler type runs as follows. A pre-1980 cast-iron boiler with a standing pilot gets 55–70%. A non-condensing 1990s–2000s model gets 70–80%. Condensing boilers do 85–88% with a 75–80 °C flow, 90–93% with 50–55 °C, and 93–96% when paired with underfloor heating at 35–45 °C.

Fuel data: natural gas is counted per kWh on the bill and emits 0.202 kg CO₂ per kWh of fuel. LPG is about 7.1 kWh per litre at 0.227 kg. Heating oil is about 10 kWh per litre at 0.267 kg.

Getting the most from the new boiler

  • Turn the flow temperature down. It is free and helps any condensing boiler. Try 55 °C, then go lower while the rooms stay warm.
  • Add weather compensation, so mild days automatically get cooler water, which is when most seasonal heat is used.
  • Balance the radiators to bring the return water back cool.
  • Do not oversize. A boiler far above the true peak load cycles and wastes efficiency. To estimate the peak, use degree days.
  • Look at other options before committing for 15 years, namely heat pump vs gas boiler and heating cost comparison. Households on oil have the heating oil cost calculator for tank and delivery numbers.

Where it falls short

These are typical seasonal efficiencies from field experience, not the lab values on the box, and single installations differ by several points. The old boiler’s efficiency is the shakiest input, since overrating its flaws inflates the saving. Fuel prices, grants, service costs and the value of a more reliable system enter only through the inputs you provide. Boilers are compared within one fuel; switching fuel is outside the scope.

Method & assumptions

Useful heat = present fuel use × energy per unit × old efficiency. Fuel needed by the new boiler = useful heat × controls factor (0.94 with smart or weather compensation) ÷ new efficiency. The new efficiency depends on fuel and flow temperature (for example gas 95 / 92 / 89 / 86% at 45 / 55 / 65 / 75 °C). Saving = (old fuel − new fuel) × price, and payback = installed cost ÷ first-year saving. Net gain adds up the yearly savings, allowing for price growth, and subtracts the cost.

Frequently asked questions

What can I save with a new condensing boiler?
Fuel use falls by roughly 15% when a non-condensing boiler (about 78% seasonal efficiency) is swapped for a condensing one (about 92%), and by about 20% if controls improve as well. A home burning 18,000 kWh of gas a year at €0.10/kWh would save around €365 every year.
What is the payback time for a boiler replacement?
Fuel savings alone usually take 7–15 years, depending on how poor the old boiler is, how much fuel you burn and what it costs. Payback is quickest for very old boilers (65–72%) and for oil or LPG systems. When the old boiler has simply died, only the price gap to the better model counts.
What stops a condensing boiler from condensing?
The usual cause is water returning from the radiators too hot. Latent heat in the flue gas of a gas condensing boiler is recovered only below about 55 °C. Units left on the factory setting of a 75–80 °C flow end up performing like a good non-condensing boiler.
Which flow temperature suits a condensing boiler?
The lowest one that keeps the house comfortable: often 50–55 °C for radiators in winter, less in mild weather, which weather compensation handles automatically. Underfloor heating or oversized radiators can run at 35–45 °C, where efficiency peaks.
How efficient is an old boiler?
Seasonal efficiency is often only 55–70% for cast-iron units built before about 1980, 70–80% for non-condensing models from the 1990s and 2000s, and 88–94% for modern condensing boilers in actual homes, which is a few points below their lab ratings.
Is a heat pump better than a new boiler?
Often, if the house is reasonably well insulated: running costs and CO₂ both drop further, most of all when electricity is no more than about three times the gas price. With a 15-year commitment ahead, price up both options first.