What this tool does
A building loses heat in proportion to the indoor-outdoor temperature gap and to how long it lasts. Degree days turn that into one number per climate. Multiply by the building’s loss per degree and you have yearly demand.
Weather data is either 1991–2020 monthly normals (listed cities) or NASA POWER satellite climatology (any map point). A monthly mean smooths over cold snaps, so the tool scatters daily temperatures around it with a normal distribution (σ = 3.5 K), much as the Hitchin method in CIBSE TM41 does. Even a month averaging 10 °C then scores on its chilly days against a 10 °C base.
For the house, enter floor area and an insulation level, or paste a heat loss coefficient from a certificate or survey. The tool returns monthly and annual demand, the cold-day peak, fuel and cost.
Formulas
H (W/K) = floor area × specific loss (3.0 uninsulated … 0.25 passive house W/m²K) Heat demand (kWh) = H × HDD × 24 ÷ 1000 Peak load (kW) = H × (indoor − design temperature) ÷ 1000 Design temperature = coldest monthly mean − 10 °C
Fuel = heat demand ÷ efficiency; Cost = fuel × price
Default example
Take the defaults: a 120 m² home in London with average insulation (1.5 W/m²K), so H = 180 W/K; bases 15.5 °C for heating and 22 °C for cooling; gas boiler 90% efficient, gas €0.10/kWh.
- Climate: January averages 5.2 °C, July 18.7 °C, the year 11.4 °C. That yields about 1,844 HDD (3,320 °F·days) and only 21 CDD.
- Per degree day: 180 × 24 ÷ 1000 = 4.32 kWh.
- Per year: 4.32 × 1,844 ≈ 7,970 kWh, or 66 kWh per m².
- Design temperature 5.2 − 10 = −4.8 °C, so peak = 180 × (21 + 4.8) ÷ 1000 ≈ 4.6 kW.
- Gas: 7,970 ÷ 0.90 ≈ 8,850 kWh, costing roughly €885 a year.
Monthly, January takes about 1,380 kWh and July about 43 kWh.
Results explained
- Degree days grade how severe the winter is for your base; only compare cities that use the same one.
- Annual demand counts heat delivered into rooms, ahead of boiler or heat pump losses.
- Peak load is the cold-day output for sizing a boiler or heat pump. More than that costs extra and makes heat pumps cycle.
- kWh per degree day characterises the building itself, so you can follow bills over several years.
Benchmarks
Approximate yearly figures, heating base 15.5 °C and cooling base 22 °C:
- Madrid: HDD 1,200–1,500; CDD 250–400.
- London: HDD 1,800–2,000; CDD under 50.
- Berlin: HDD 2,300–2,500; CDD under 50.
- Chicago: HDD 2,700–3,100; CDD 150–250.
- Stockholm: HDD 3,000–3,300; CDD under 30.
- Kuala Lumpur: HDD 0; CDD over 2,000.
Specific heat loss per m² of floor, by insulation level:
- Passive house: 0.25 W/m²K.
- Good, post-2000 code: 1.0 W/m²K.
- Some upgrades, average: 1.5 W/m²K.
- Uninsulated, pre-1950: 3.0 W/m²K.
Using it well
- A tight home full of appliances may need no heat above 12–14 °C outdoors, so a 15.5 °C base would overstate it.
- Test the model: last winter’s heating energy divided by that period’s degree days should resemble the tool’s kWh per degree day.
- Choose equipment by the peak figure. Running costs can then be checked with the heat pump calculator or the heating cost comparison.
- Raise the insulation level and watch demand and peak drop; for the cost of the work, go to insulation savings.
Accuracy
Monthly-mean estimates typically land within 5–15% of daily-record values, and one year can differ from the normal by a similar margin. The model leaves out thermal mass, ventilation habits and any solar gain beyond what the base temperature implies. Cooling is sensible heat only, with no solar, internal gains or humidity, so actual air-conditioning loads run higher. NASA’s grid is about 50 km, which can miss cities, valleys and coasts.
Method & assumptions
To get a month's HDD, add up max(0, base − daily mean) for every day. Only the monthly mean is known, so daily means are modelled as normally distributed (σ = 3.5 K). Yearly demand = H × HDD × 24 ÷ 1000, where H (W/K) is the building's heat loss coefficient: floor area × specific loss by insulation level (3.0 W/m²K uninsulated … 0.25 passive house). Peak load = H × (indoor − design temperature), with the design temperature set at the coldest monthly mean − 10 °C. Fuel = heat ÷ efficiency.
Frequently asked questions
What is a heating degree day?
Which base temperature is right?
How do degree days become kWh of heat?
London: how many HDD per year?
Why do cooling degree days matter?
Mild winter versus cold winter: how do I compare my bills?
Sources & references
Embed this calculator