Thermal bridge
A spot in a building's envelope where heat flows much faster than around it, because of the shape or because of more conductive materials.
A thermal bridge, also called a cold bridge, occurs where insulation is broken, pierced or thinner, or where the shape focuses heat loss. Familiar cases are concrete balcony slabs running through the facade, steel lintels, junctions of wall with floor or roof, window reveals, timber or steel studs, and fixings through external insulation.
Point thermal bridge: Q = χ x ΔT (χ in W/K)
Total heat loss coefficient: H = Σ U·A + Σ ψ·L + Σ χ
Example: balcony ψ = 0.7 W/m·K, 10 m, ΔT 20 K: 140 W
Values of ψ span about 0.01 W/m·K for carefully detailed junctions up to 0.5–1.0 W/m·K for an uninsulated balcony slab. In ordinary buildings, bridges can add 10–30% to the heat lost through the fabric. A passive house aims for "thermal-bridge-free" design, with ψ ≤ 0.01 W/m·K at external dimensions.
Bridges also cool the inside surface, which risks condensation and mould. To avoid mould, the temperature factor f_Rsi (lowest surface temperature relative to the indoor-outdoor difference) should typically be above 0.75 (ISO 13788). Remedies are structural thermal breaks for balconies, continuous external insulation and insulated window installation. Assessment relies on 2D/3D numerical models under ISO 10211, or on thermography.
Related terms
All terms →- U-value
A building element's heat-loss rate: watts passing through each square metre for every kelvin of temperature difference (W/m²K). Smaller values mean better insulation.
- R-value
How strongly a material layer or assembly resists heat flow, as the reciprocal of U-value; the higher, the better.
- Passive house (Passivhaus)
A strict building standard from 1990s Germany that reaches very low heating demand with heavy insulation, airtight construction and heat-recovery ventilation.
- Energy Performance Certificate (EPC)
A standardised grade, usually A to G, for a building's calculated energy performance; the EU and UK demand one when a property is sold or let.
- Heating degree days (HDD)
Tallies how cold and for how many days the outdoor temperature stays under a chosen base, so heating demand can be estimated and compared across years.