R-value
How strongly a material layer or assembly resists heat flow, as the reciprocal of U-value; the higher, the better.
Use the R-value to rate how well a layer holds back conducted heat. In a homogeneous layer, it is thickness over thermal conductivity. Series layers simply sum their resistances, so R-values make it easy to plan a build-up of insulation, and the total of the assembly can be turned into a U-value.
R_total = R_si + R_1 + R_2 + ... + R_se; U = 1 / R_total
US units: 1 ft²·°F·h/BTU = 0.1761 m²K/W
R (US) = R (SI) x 5.678
Example: 150 mm mineral wool at λ = 0.035: R = 4.29 m²K/W ≈ R-24 (US)
American products are sold with an imperial R-value for their installed thickness. DOE recommendations include R-13 to R-21 in 2x4 and 2x6 stud walls and R-38 to R-60 in attics in cold climates. In Europe and most other places, SI values apply, and codes normally state U-values in place of R-values.
Limits to keep in mind: an R-value presumes steady-state conduction and dry material. It says nothing about air leakage, convection loops behind loosely fitted insulation, radiation, or thermal bridging through studs and fasteners. Framing can pull a wall insulated with R-19 batts down to an effective whole-wall value of around R-14.
Related terms
All terms →- U-value
A building element's heat-loss rate: watts passing through each square metre for every kelvin of temperature difference (W/m²K). Smaller values mean better insulation.
- Thermal bridge
A spot in a building's envelope where heat flows much faster than around it, because of the shape or because of more conductive materials.
- Passive house (Passivhaus)
A strict building standard from 1990s Germany that reaches very low heating demand with heavy insulation, airtight construction and heat-recovery ventilation.
- Heating degree days (HDD)
Tallies how cold and for how many days the outdoor temperature stays under a chosen base, so heating demand can be estimated and compared across years.
- Energy Performance Certificate (EPC)
A standardised grade, usually A to G, for a building's calculated energy performance; the EU and UK demand one when a property is sold or let.