U-value
A building element's heat-loss rate: watts passing through each square metre for every kelvin of temperature difference (W/m²K). Smaller values mean better insulation.
Use the U-value to rate how quickly heat escapes through a wall, roof, floor or window. It already includes the resistance of the air films at both surfaces, and it equals one divided by the whole assembly's thermal resistance (see R-value).
Heat loss Q (W) = U x A x ΔT
Example: 100 m² wall, U = 0.25, ΔT = 20 K: 500 W
Conversion: U (BTU/h·ft²·°F) = U (W/m²K) / 5.678
Symbols: layer thickness d (m), conductivity λ (W/m·K), and surface resistances R_si (inside) and R_se (outside), typically 0.13 and 0.04 m²K/W for walls.
Rough benchmarks in W/m²K:
- Solid brick wall without insulation: 1.5–2.1
- EU code-compliant new wall: 0.15–0.30
- Passive house walls and roofs: 0.10–0.15
- Windows, single pane: about 5.0–5.8
- Windows, low-e double glazing with argon: 1.1–1.4
- Windows, triple glazing: 0.5–0.8
Insulants vary too. Mineral wool and EPS conduct at λ of roughly 0.032–0.040 W/m·K, PIR at about 0.022 and aerogel at about 0.015. Once built, a wall often underperforms the paper figure, since thermal bridges, gaps and damp all add loss. Regulations set a maximum U-value per element.
Related terms
All terms →- R-value
How strongly a material layer or assembly resists heat flow, as the reciprocal of U-value; the higher, the better.
- Thermal bridge
A spot in a building's envelope where heat flows much faster than around it, because of the shape or because of more conductive materials.
- Passive house (Passivhaus)
A strict building standard from 1990s Germany that reaches very low heating demand with heavy insulation, airtight construction and heat-recovery ventilation.
- Heating degree days (HDD)
Tallies how cold and for how many days the outdoor temperature stays under a chosen base, so heating demand can be estimated and compared across years.
- Energy Performance Certificate (EPC)
A standardised grade, usually A to G, for a building's calculated energy performance; the EU and UK demand one when a property is sold or let.