Glossary · Heating & buildings

U-value

A building element's heat-loss rate: watts passing through each square metre for every kelvin of temperature difference (W/m²K). Smaller values mean better insulation.

Use the U-value to rate how quickly heat escapes through a wall, roof, floor or window. It already includes the resistance of the air films at both surfaces, and it equals one divided by the whole assembly's thermal resistance (see R-value).

U = 1 / R_total = 1 / (R_si + Σ d_i/λ_i + R_se)
Heat loss Q (W) = U x A x ΔT
Example: 100 m² wall, U = 0.25, ΔT = 20 K: 500 W
Conversion: U (BTU/h·ft²·°F) = U (W/m²K) / 5.678

Symbols: layer thickness d (m), conductivity λ (W/m·K), and surface resistances R_si (inside) and R_se (outside), typically 0.13 and 0.04 m²K/W for walls.

Rough benchmarks in W/m²K:

  • Solid brick wall without insulation: 1.5–2.1
  • EU code-compliant new wall: 0.15–0.30
  • Passive house walls and roofs: 0.10–0.15
  • Windows, single pane: about 5.0–5.8
  • Windows, low-e double glazing with argon: 1.1–1.4
  • Windows, triple glazing: 0.5–0.8

Insulants vary too. Mineral wool and EPS conduct at λ of roughly 0.032–0.040 W/m·K, PIR at about 0.022 and aerogel at about 0.015. Once built, a wall often underperforms the paper figure, since thermal bridges, gaps and damp all add loss. Regulations set a maximum U-value per element.

Related terms

All terms →
  • R-value

    How strongly a material layer or assembly resists heat flow, as the reciprocal of U-value; the higher, the better.

  • Thermal bridge

    A spot in a building's envelope where heat flows much faster than around it, because of the shape or because of more conductive materials.

  • Passive house (Passivhaus)

    A strict building standard from 1990s Germany that reaches very low heating demand with heavy insulation, airtight construction and heat-recovery ventilation.

  • Heating degree days (HDD)

    Tallies how cold and for how many days the outdoor temperature stays under a chosen base, so heating demand can be estimated and compared across years.

  • Energy Performance Certificate (EPC)

    A standardised grade, usually A to G, for a building's calculated energy performance; the EU and UK demand one when a property is sold or let.