The method in brief
A lot of online tools multiply a single mean speed by a constant. Two things matter more: the year-round spread of wind speeds and the speed at the rotor’s hub. This calculator models both rather than assuming them away.
After you select a location, it pulls 8,760 hourly NASA POWER records (wind at 10 m and 50 m, temperature, site elevation) and, hour by hour:
- raises wind to hub height. The shear exponent comes from NASA’s own 10 m and 50 m series, split by month and by hour of day, because calm clear nights shear much harder than afternoons. A terrain class or a custom α can replace it;
- adjusts for air density, using elevation and temperature. At 1,000 m the air is about 10% lighter than at the coast;
- reads off the power curve at the density-corrected speed, following the IEC 61400-12-1 normalisation;
- adds up the year and subtracts losses from wakes, downtime, electrical equipment and other sources.
Manual mode needs no download. Type a mean speed (the Global Wind Atlas or your own mast will do), the measurement height and Weibull k. The power curve is then integrated over a Weibull distribution; the Weibull calculator explains that part.
Equations
AEP_net = Σ_hours P(v_hub,t) × (1 − wake) × availability × (1 − electrical) × (1 − other) Capacity factor = AEP_net / (P_rated × 8,760 h)
In these, A = π·D²/4 is the swept rotor area, and Cp is the power coefficient, which the Betz limit (59.3%) caps. Large modern rotors top out at 45–48%, small turbines at 25–35%. For that reason the built-in generic curves make peak Cp depend on turbine size.
Case study: a 3.6 MW turbine near Cogealac
The preset is one low-wind 3.6 MW turbine with a 136 m rotor on a 120 m tower in Dobrogea, the windiest part of Romania. Using 2024 NASA weather, the fitted shear exponent is about 0.16. That gives roughly 7.1 m/s at hub height and a power density near 360 W/m².
Gross production simulates at about 14,200 MWh. Subtract 3% for unavailability, 2% electrical and 3% other, and the farm gate sees roughly 13,000 MWh per year: a capacity factor near 41%, or the usage of 3,500+ typical EU households. Winter is strong, with January and February each producing over double what June or August do.
Economics: the machine costs about €4.9 million at 1,350 €/kW. At €75 per MWh, year-one sales come close to €1 million; with O&M of €40/kW/yr, payback is under six years and LCOE about €44/MWh. A single turbine suffers no wake loss, so in a full farm at this site, take off another 5–10%.
Making sense of the numbers
- Net annual energy is what the turbine delivers in year one once everything is deducted.
- Capacity factor and full-load hours compare sites or machines of any size. 3,000 full-load hours corresponds to a 34% capacity factor.
- Hub-height mean wind with the IEC class (I–IV) points to the turbine family built for the site. Class III–IV machines are low-wind types whose rotors are large for their generators.
- Specific power (W per m² of rotor) is the main design variable. Values of 200–260 W/m² fit moderate wind and give high capacity factors; 350+ W/m² fits strong offshore wind.
- Histogram of hours per year in 1 m/s bins, overlaid with the power curve: nearly all energy arrives in the bins just under rated speed, and rare storm hours add little.
Reference ranges
| Turbine class | Rotor Ø | Hub height | Mean wind at hub | Typical capacity factor |
|---|---|---|---|---|
| Micro (1–3 kW) | 2–4 m | 10–18 m | 4–5 m/s | 8–18% |
| Small (5–20 kW) | 6–10 m | 18–36 m | 4.5–6 m/s | 12–25% |
| Medium (100 kW) | 20–27 m | 30–50 m | 5–6.5 m/s | 18–30% |
| Onshore 2–3 MW | 90–120 m | 80–120 m | 6.5–8 m/s | 28–40% |
| Onshore 4–7 MW | 140–175 m | 120–170 m | 6.5–8.5 m/s | 33–48% |
| Offshore 8–15 MW | 165–240 m | 110–150 m | 9–10.5 m/s | 40–55% |
What raises output
- Tower height. In rough terrain each added 10 m can bring 3–5% more energy. For small turbines, the critical step is lifting the rotor at least 10 m clear of every obstacle within 150 m.
- Rotor choice. At a moderate site a 4 MW turbine with a 150 m rotor beats a 5 MW turbine with a 130 m rotor.
- Clean air. Rooftops, trees and buildings make turbulent, gusty flow that small turbines cope with badly; 30–50% less than the brochure figure is common.
- Layout. Leave 3–5 rotor diameters crosswind and 6–10 downwind to keep wake loss under 10%. The wind farm calculator shows the effect.
- Weather year. Wind energy varies ±10% between years. The advanced options let you swap the year.
Known simplifications
The power curves are generic, derived from rotor size and rated power. Modern pitch-regulated machines match within a few percent, but a certified manufacturer curve is better. NASA reanalysis smooths out local terrain, and hourly averages conceal turbulence. Curtailment by the grid operator, icing, noise limits and bat-protection shutdowns are only included if you enter them under other losses. Financial figures are pre-tax and omit grid fees and financing; for debt and equity returns, switch to the wind farm calculator.
Method & assumptions
Wind at hub height. NASA POWER gives hourly speeds at two heights, 10 m and 50 m. In auto mode, the exponent α = ln(v₅₀/v₁₀)/ln 5 is derived per month and per hour of day, kept within 0.06–0.40, which lets stable nights differ from mixed afternoons. Every hour is then scaled by v_hub = v₅₀ (h/50)^α. Or pick a terrain roughness class, or enter α yourself.
Air density is computed hourly. Site elevation plus hub height feed the barometric formula, and air temperature is lapsed to hub height. Following IEC 61400-12-1, wind speed is normalised for density as v·(ρ/1.225)^⅓ ahead of the power curve.
Power curve. The curve is generic, P = ½ρACp(v)v³, and levels off smoothly at rated power. Peak Cp grows with turbine size, from ≈0.28 (micro) to 0.46 (utility-scale rotors). With manual input, a Weibull distribution defined by your mean speed and shape k provides the hours at each speed.
Net energy = gross × (1 − wake) × availability × (1 − electrical) × (1 − other), and capacity factor = net energy ÷ (rated power × 8,760 h). Revenue is projected over the project life with degradation, price escalation and 2%/yr growth in O&M. LCOE = discounted cost ÷ discounted energy.
Frequently asked questions
How many kWh does a wind turbine make in a year?
Which capacity factors are considered good?
How windy must a site be?
What do wind turbines cost per kW?
What makes tall towers pay off?
How good is NASA's wind dataset for siting?
Sources & references
- NASA POWER — Prediction Of Worldwide Energy Resources (hourly MERRA-2 wind at 10 m and 50 m)
- IEC 61400-12-1: Wind energy generation systems — Power performance measurements of electricity producing wind turbines
- IRENA — Renewable Power Generation Costs in 2023
- NREL Annual Technology Baseline (land-based and offshore wind)
- Burton, T., Jenkins, N., Sharpe, D., Bossanyi, E. — Wind Energy Handbook, 2nd ed., Wiley
Embed this calculator
Free for bloggers, installers, schools and NGOs. Copy the snippet below and it stays current by itself.