Glossary · Hydro & ocean

Tidal stream power

Power from submerged turbines in strong tidal currents. They resemble wind turbines, but the medium is water, roughly 800 times denser than air.

These devices work in places where the sea runs fast between land: straits, sounds, and the waters off headlands. They take kinetic energy from the moving water and need no dam. Water that dense (about 1,025 kg/m³) packs a lot of power into a small area:

P = ½ ρ A v³ Cp

Compare the two media. A 2.5 m/s peak spring current delivers about 8 kW per m² of rotor area; wind at 12 m/s delivers roughly 0.5 kW/m². Developers look for peak spring currents above about 2–2.5 m/s in 25–50 m of water.

Designs vary. Some turbines are horizontal-axis and sit on the seabed (Meygen in Scotland, 6 MW, is the largest array). Others hang below a floating platform (Orbital O2, 2 MW), or are vertical-axis or ducted. Rotors measure 15–26 m across and turn slowly because cavitation limits tip-speed ratios. The Betz limit holds, although blockage in a channel may raise the effective ceiling.

  • Capacity factor: about 30–45%; the astronomical tides make it easy to forecast
  • Practical resource worldwide: 100–150 TWh/yr, estimated for well-studied sites such as the Pentland Firth, Raz Blanchard, Bay of Fundy and Indonesian straits
  • Cost: pre-commercial LCOE often quoted at EUR 200–300/MWh (Ocean Energy Europe, JRC); UK CfD awards of 2022–2024 were roughly GBP 180–200/MWh in 2012 prices

Hard parts of the job: marine growth, corrosion, severe turbulence loading, and work at sea that is only possible in brief slack-water windows.

Related terms

All terms →
  • Tidal range power

    Power generation that exploits the difference in height between high and low tide: a barrage or lagoon traps the water, which then runs out through low-head turbines.

  • Wave energy

    Power drawn from the movement of the sea surface, through point absorbers, oscillating water columns, attenuators and similar devices; pre-commercial so far.

  • Betz limit

    The theoretical ceiling on the share of wind kinetic energy an open rotor can capture: 16/27, about 59.3%.

  • Swept area

    Swept area is what a turbine's spinning blades cover: a circle. Power output rises in direct proportion to it, so doubling the rotor diameter quadruples it.

  • Tip-speed ratio

    The speed of a blade tip relative to the undisturbed wind. For three-bladed utility turbines the design value lies at about 7 to 10.

  • Contract for Difference (CfD)

    A contract or support scheme that pays a generator the gap between an agreed strike price and a market reference price, and takes money back from it when the market price is higher.