Hydro generation that takes water from a river's natural flow with hardly any reservoir, so output rises and falls with the river and not with demand.

Water is held back by a weir or low dam and drawn into an intake. A canal or penstock may carry it onward to build up head before it re-enters the river further down. Run-of-river (RoR) plants keep only a few hours of pondage at most, so output tracks the seasons: strong during snowmelt or rains, weak in dry spells.

The usual hydropower equation gives the power:

P = η ρ g Q H

η is overall efficiency (0.80–0.90 for large units), ρ = 1,000 kg/m³, g = 9.81 m/s², Q is flow (m³/s) and H is net head (m). Worked example: 50 m³/s dropping through 20 m at 88% efficiency delivers about 8.6 MW.

What sets these plants apart:

  • Capacity factor: 40–65% where well sited; it depends on the design flow picked from the flow duration curve
  • Turbines: Kaplan and bulb units for broad, low-head rivers; Francis or Pelton for steep, high-head mountain diversions
  • Examples: Rhine and Danube cascades, Jirau and Santo Antônio on the Madeira (about 3.5–3.75 GW each), Alpine and Himalayan diversion schemes

With no large reservoir, run-of-river largely escapes flooding of big areas and reservoir methane. Diversions can still dry out part of the river, so minimum environmental flows and fish passages are required. Output cannot be dispatched at will, which makes RoR closer to a variable renewable than to reservoir hydro. Almost all micro and small hydro below 10 MW is run-of-river.

Related terms

All terms →
  • Hydraulic head

    Vertical distance from the water level at a hydropower intake down to the turbine outlet (tailwater); multiplied with flow, it fixes the power on offer.

  • Kaplan turbine

    Propeller-type reaction turbine for hydro plants; both its runner blades and its wicket gates can be adjusted, so it suits low heads (about 2 to 40 m) and high flows.

  • Francis turbine

    A reaction hydro turbine with fixed blades, where water flows in radially and out axially; the most installed design, suited to medium heads of about 30 to 700 m.

  • Pelton turbine

    An impulse turbine for hydro power: fast jets of water hit double-cupped buckets around a wheel. It is the standard pick when the head is above roughly 250 m.

  • Capacity factor

    Actual energy a power plant generates in a period divided by what it would generate at full nameplate capacity throughout that period.