Renewables · energy technology

Ocean Energy: Tidal, Wave and OTEC Power

Tides, waves and ocean heat: large and predictable resources that are still at an early commercial stage.

Capacity listed in plant database
0.6GW
4 countries · WRI GPPD
Capacity factor
20–40%
typical annual range
Levelised cost
200–450$/MWh
Pre-commercial arrays per Ocean Energy Europe; ocean technology briefs by IRENA
Lifecycle emissions
17gCO₂e/kWh
IPCC AR5 median, range 5.6–28

Installed capacity recorded in the worldwide plant database

Power plant map →
#CountryCapacity (MW)% of listed
1🇰🇷South Korea25446.0%
2🇫🇷France24043.5%
3🇬🇧United Kingdom386.9%
4🇨🇦Canada203.6%

WRI Global Power Plant Database v1.3 (plants of about 1 MW and up, data from 2019–2021). Listed in total: 0.6 GW across 4 countries. It suits geographic questions; for present-day capacity, turn to IRENA or national statistics.

Key characteristics

Compare all →
VariantCapacity factorCost $/MWhgCO₂e/kWhLand m²/MWhDeaths/TWhBuild (yrs)
Marine (tidal & wave)20–40%200–45017 (5.6–28)≈0 (sea area)—2–5

Costs come from Pre-commercial arrays per Ocean Energy Europe; ocean technology briefs by IRENA. IPCC AR5 WGIII Annex III supplies the emissions (median, min–max). Death rates are Markandya & Wilkinson (2007) and Sovacool et al. (2016), reached via Our World in Data.

Ocean energy, or marine energy, draws power from seawater’s motion, temperature or salt content: tides, tidal currents, waves, thermal gradients and fresh-meets-salt mixing. On paper the supply is enormous: the 2011 Special Report on Renewable Energy Sources from the IPCC estimates a theoretical global resource of several thousand to tens of thousands of TWh a year for waves and thermal gradients combined, and few energy flows are as forecastable as the tides. In practice the industry is minute. Worldwide about 0.5 GW is running, producing roughly 1 TWh annually (below 0.01% of global electricity), and two tidal barrages provide almost all of it. Below: each technology, the reasons for slow progress, and the present state of costs and installations.

Common challenge, different physics

All ocean devices share one problem: the sea punishes equipment. Extreme wave loads, corrosion, biofouling and storms hit hardware, and installation and repair wait for short weather windows and specialist ships. The underlying physics differs by technology.

Tidal range (barrages and lagoons)

Think of tidal range power as hydropower at very low head. An estuary barrage or an offshore lagoon wall traps water at high tide. When the sea outside has fallen several metres, the water returns through low-head bulb turbines. Two-way generation, using the incoming tide as well, is an option, as is pumping at high tide to raise the head. Since energy per tide scales with the range squared, development is worthwhile only where tides are large, generally above about 5 m.

Tidal range — potential energy per tide (one-way, ideal): E = ½ × ρ × g × A × h²

Tidal stream — power through a rotor: P = ½ × ρ × A_rotor × v³ × Cp

ρ = seawater density (≈ 1,025 kg/m³) g = 9.81 m/s² A = basin area (m²) h = tidal range (m) A_rotor = swept area (m²) v = current speed (m/s) Cp ≈ 0.35–0.45

Example: basin 20 km², range 8 m → E ≈ ½ × 1,025 × 9.81 × 2×10⁷ × 64 ≈ 6.4×10¹² J ≈ 1.8 GWh per tide (theoretical)

Plants capture a third or less of the theoretical amount, since turbines cannot work across the whole head range and navigation and ecology set limits. Output for either approach can be estimated with the tidal energy calculator.

Tidal stream

Tidal stream machines are placed where currents run hard, in straits and around headlands, with peak speeds often above 2–2.5 m/s. Water is about 840 times denser than air, which lets a tidal rotor be much smaller than a wind rotor of equal power; a 2.5 m/s current matches the power density of roughly a 24 m/s wind. The cube law and Betz limit apply as in wind power. Layouts differ. Some turbines stand on the seabed with horizontal axes. Others hang beneath a floating platform, as with Orbital Marine Power’s 2 MW O2. A third group are kite-like machines that swoop through the current.

Wave energy

Wave energy converters harvest surface-wave motion, energy that wind delivered across long ocean stretches. The best resource, often 40–70 kW per metre of crest, lies on west-facing mid- to high-latitude coasts: Scotland, Ireland, Portugal, Chile, southern Australia, the US Pacific Northwest. Power density scales with the square of wave height and with wave period. Wind power converged on the three-bladed rotor; waves have no consensus design:

  • Point absorbers: buoys whose heave drives a hydraulic or linear electric generator.
  • Oscillating water columns (OWC): a partly submerged chamber where waves push air past an air turbine. Spain’s Mutriku breakwater plant (about 0.3 MW) has operated since 2011.
  • Attenuators: long jointed floats that flex as waves pass, like Pelamis.
  • Surge converters: hinged seabed flaps near shore that waves swing back and forth, as in Aquamarine’s Oyster.
  • Overtopping devices: waves spill into a raised reservoir that drains through low-head turbines.

OTEC

OTEC places a heat engine between hot surface water in the tropics and cold water lifted from roughly 1,000 m. Closed-cycle designs vaporise a fluid such as ammonia. Open-cycle designs turn warm seawater into low-pressure steam, which also allows desalinated water as a by-product. Because the temperature difference is just about 20–24 °C, Carnot efficiency is near 7% and net efficiency, once pumping is subtracted, about 2–3%. That demands immense water flows and long cold-water pipes. About 100 kW is the size of the demonstrators in Hawaii (Makai Ocean Engineering) and Okinawa, Japan. The main audience is tropical islands paying for expensive diesel power.

Salinity gradient

Where river meets sea, the salt difference can be converted into electricity. Two methods exist. In pressure-retarded osmosis, fresh water passes through membranes into pressurised seawater. Reverse electrodialysis builds up voltage across ion-selective membranes. Norway’s Statkraft operated a small osmotic prototype at Tofte between 2009 and 2013, then concluded that the membranes were too weak for commercial use. Still laboratory and pilot scale.

Major projects

Project Country Type Capacity Status / notes
Sihwa Lake South Korea Tidal range (lagoon on existing seawall) 254 MW Since 2011; largest ocean plant, flood-tide generation
La Rance France Tidal range barrage 240 MW Since 1966; roughly 500 GWh/yr
Annapolis Royal Canada Tidal range barrage 20 MW 1984–2019; closed over fish-mortality concerns
Jiangxia, Uldolmok, LHD Zhoushan China / South Korea Tidal range & stream pilots ~1–4 MW each Demonstration scale
MeyGen, Pentland Firth United Kingdom Tidal stream array 6 MW (Phase 1A) Since 2016–2017; tens of GWh exported, expansion contracted
Orbital O2, Orkney United Kingdom Floating tidal stream 2 MW Since 2021
Mutriku Spain Wave (oscillating water column) ~0.3 MW Since 2011, built into a breakwater
Makai OTEC, Hawaii United States OTEC (closed cycle) ~0.1 MW Grid-connected demonstrator since 2015

Britain’s biggest tidal range proposals keep being rejected over cost and environmental impact. They include the 8.6 GW Severn Barrage (approximate size) and the 320 MW Swansea Bay Tidal Lagoon.

Performance

  • Tidal stream: power coefficient 0.35–0.45; capacity factor about 25–45%, depending on how rated power is set against peak current. In good years MeyGen’s turbines have been available more than 90% of the time.
  • Tidal barrages: about 20–30%, because generation covers only part of each cycle. La Rance yields roughly 500 GWh a year from 240 MW, about 24%.
  • Wave: 20–35% is expected from mature devices at good sites, though hardly any have operated long enough to confirm it.
  • OTEC: stable ocean temperatures mean baseload operation above 90% is possible in principle.

Tidal energy’s real strength is predictability. Forecasts reach years ahead. Because tides peak at different moments along a coastline, sites far apart can even out the combined supply. It remains a variable renewable, though without the forecast errors that weather causes.

Costs

Ocean energy is far from competitive with established renewables, chiefly because so little has been built that learning effects, which cut wind and solar costs, have not happened. Published LCOE estimates differ widely:

  • Tidal stream: today’s pilot arrays sit at roughly EUR 0.20–0.45/kWh, according to IRENA (Innovation Outlook: Ocean Energy Technologies, 2020) and Ocean Energy Europe. Britain’s Contracts for Difference paid tidal stream about £178/MWh in Allocation Round 4 (2022), then £170–200/MWh (2012 prices). Offshore wind got less than a third of that in the same rounds.
  • Wave: costlier again; early arrays are commonly put at EUR 0.30–0.55/kWh or more, with wide uncertainty.
  • Tidal range: upfront CAPEX is very high, yet the civil works last 100 years and running costs stay low. La Rance recovered its cost long ago; new lagoon proposals struggle to show competitive LCOE at commercial discount rates.
  • OTEC: commercial plants of 10–100 MW are guesswork, often put at USD 0.15–0.40/kWh, and none exists at that scale to check the guess.

Targets in the European Commission’s SET Plan: tidal stream EUR 0.15/kWh by 2025 and EUR 0.10/kWh by 2030; wave EUR 0.20/kWh by 2025 and EUR 0.15/kWh by 2030. Getting there means cumulative installations rising from tens to hundreds of megawatts. Compare with other options in the LCOE calculator.

Space, water, materials

The space used is sea rather than land. Exclusion zones around tidal stream and wave arrays may collide with shipping, fishing and recreation; area per MW is comparable to offshore wind. Barrages and lagoons are different, permanently altering large intertidal zones and estuaries. Steel, concrete and composites make up most of the material, along with copper subsea cables; corrosion protection and anti-fouling coatings add chemical issues. No freshwater is used, and open-cycle OTEC can make some.

Life-cycle CO2

Only a few installations, mostly prototypes, underlie these assessments, so treat the figures as indicative. In IPCC AR5 WGIII Annex III (2014), tidal and wave power span about 5.6–28 gCO2e/kWh, median near 17, close to wind and solar. Early devices sit high in the range because they are steel-heavy with low capacity factors; larger, better-designed arrays should drop lower. As with hydro dams, the carbon in a barrage’s concrete dominates, but it is spread across a very long lifetime. See lifecycle emissions for how these figures are derived.

Safety and environment

Human safety record is good; risks are mainly those of offshore work. Environmental questions vary by site:

  • Barrages: they change tidal flow, sediment and water quality, and affect the mudflats where birds feed. After construction the La Rance estuary needed about ten years to find a new ecological balance. Fish passing low-head turbines get injured, and fish-mortality worries helped close Annapolis Royal.
  • Tidal stream turbines: collision concerns for marine mammals, diving birds and fish. Monitoring at MeyGen and at US and Canadian sites has so far recorded very few encounters, and blade tips move far slower than ship propellers. The evidence base, however, remains small.
  • Noise and fields: installation noise (mostly pile driving) and electromagnetic fields around cables have been studied; for small arrays they are usually considered minor.
  • OTEC: the discharge of large amounts of cold, nutrient-rich deep water could upset local ecosystems if not handled carefully.

Outlook

Ocean energy resembles offshore wind in the early 2000s: proven in principle, costly and reliant on public support. Tidal stream leads the newer technologies, with the UK, France, Canada and China at the front. Thanks to ring-fenced revenue support, over 100 MW of tidal stream is under contract in the UK; projects in France’s Raz Blanchard aim to repeat that. Wave remains pre-commercial after several high-profile failures; Developers are being nudged toward shared designs by Wave Energy Scotland and by the US Department of Energy’s PacWave test site, among others. Tidal range could be huge at a handful of sites, but environmental and funding hurdles are steep. OTEC and salinity gradient stay niche.

Three arguments support a long-term role: forecastable output, a generation profile that peaks at other times than wind and solar, and local power for islands and remote coasts. Both Ocean Energy Europe and the IEA’s Ocean Energy Systems programme project tens of gigawatts across Europe by 2050 on the condition that costs fall as expected. Wind and solar will still dwarf that. Offshore wind, the technology comparison and the world energy map show where ocean energy stands among renewables.

Frequently asked questions

How much ocean power is installed in the world?
Around 0.5 GW, more than 90% of it in two tidal barrages: Sihwa Lake in South Korea (254 MW) and La Rance in France (240 MW). All operating tidal stream and wave devices together add only some tens of megawatts, mainly in Europe and China.
Tidal range versus tidal stream: what is the difference?
Tidal range exploits the height difference between sea and basin: a barrage or lagoon holds water at high tide and releases it through turbines after the outside level falls. Tidal stream needs no dam; turbines sit directly in fast currents, much like underwater wind turbines. Range schemes need heavy civil works. Stream devices are less intrusive, but sites with strong enough currents are scarcer.
Can tides be forecast?
Accurately, decades ahead, because the Moon's and Sun's gravity drive them. Output swings with each cycle of roughly 12.4 hours and with the 14.8-day spring–neap cycle, but weather hardly affects it, which sets tides apart from wind or solar. Grid planners value that.
Why has wave energy not taken off?
The energy in waves is plentiful, but a machine has to withstand storm loads far beyond its normal working loads, in corrosive water where maintenance is expensive. Dozens of concepts have been tested; well-known developers, Pelamis and Aquamarine Power among them, folded before reaching commercial scale. Costs still exceed wind and solar by a wide margin.
What does tidal power cost?
According to IRENA and Ocean Energy Europe, current tidal stream pilot arrays generate at roughly EUR 0.20–0.45/kWh, a multiple of offshore wind. In 2022–2024 UK auctions, tidal stream won contracts for difference at strike prices of about £170–200/MWh (2012 prices). Industry roadmaps target EUR 0.10/kWh around 2030 if deployment reaches hundreds of megawatts.
What is OTEC?
Ocean thermal energy conversion exploits the contrast between tropical surface water (around 25–28 °C) and water from 800–1,000 m depth (around 4–5 °C) to run a heat engine. A gap of just 20 °C or so keeps thermal efficiency near 3% or below, and enormous water volumes must be pumped. Only demonstration units of up to about 100 kW exist, in Hawaii and Okinawa.

Sources & references

  1. IRENA (2020). Innovation Outlook: Ocean Energy Technologies
  2. Ocean Energy Europe. Ocean Energy Key Trends and Statistics (annual)
  3. Ocean Energy Systems (IEA Technology Collaboration Programme). Annual Report
  4. IPCC (2014). AR5 WGIII Annex III: Technology-specific Cost and Performance Parameters
  5. IPCC (2011). Special Report on Renewable Energy Sources (SRREN), Chapter 6: Ocean Energy
  6. JRC (2023). Clean Energy Technology Observatory: Ocean Energy in the European Union