Tidal range power
Power generation that exploits the difference in height between high and low tide: a barrage or lagoon traps the water, which then runs out through low-head turbines.
Low-head hydro and tidal range plants share one design principle; with tides, the head is made by the sea. At high tide, a barrage over an estuary or an artificial lagoon traps seawater. The falling tide then drives the stored water through bulb turbines. Plants may generate during ebb alone, flood alone, or both.
Theoretical energy per tidal cycle, for a basin of area A and tidal range R:
Range enters squared, which is why sites need a mean range above roughly 5 m to be considered viable. Candidates include the Severn Estuary (UK, up to about 14 m), Bay of Fundy (Canada, up to 16 m), the Rance (France), Gulf of Khambhat (India), and locations in Korea and Russia.
Plants that exist:
- Sihwa Lake (South Korea, 2011): 254 MW, the biggest, which generates on the flood tide only
- La Rance (France, 1966): 240 MW and about 500 GWh a year, using 24 bulb turbines
- Small ones at Annapolis Royal (Canada, now closed) and Jiangxia (China)
Tides can be forecast accurately for years. They arrive about 50 minutes later each day and vary through the spring-neap cycle, giving capacity factors of about 20–30%. Costs are high, construction slow and the ecological impact on estuary sediments, birds and fish significant; together they have halted large schemes such as the Severn Barrage and Swansea Bay lagoon. A life of 100 years or more can reduce lifetime cost, but only if discount rates are low.
Related terms
All terms →- Tidal stream power
Power from submerged turbines in strong tidal currents. They resemble wind turbines, but the medium is water, roughly 800 times denser than air.
- Kaplan turbine
Propeller-type reaction turbine for hydro plants; both its runner blades and its wicket gates can be adjusted, so it suits low heads (about 2 to 40 m) and high flows.
- Wave energy
Power drawn from the movement of the sea surface, through point absorbers, oscillating water columns, attenuators and similar devices; pre-commercial so far.
- Capacity factor
Actual energy a power plant generates in a period divided by what it would generate at full nameplate capacity throughout that period.
- Hydraulic head
Vertical distance from the water level at a hydropower intake down to the turbine outlet (tailwater); multiplied with flow, it fixes the power on offer.