Renewables · energy technology

CSP: Solar Thermal Power With Storage

Mirrors focus sunlight onto molten salt or oil to raise steam, and thermal storage lets the plant keep producing at night.

Capacity factor
30–55%
typical annual range
Levelised cost
70–200$/MWh
IRENA, Renewable Power Generation Costs in 2023 (2024)
Lifecycle emissions
27gCO₂e/kWh
IPCC AR5 median, range 8.8–63
Build time
2–4years
construction, excl. permitting

Key characteristics

Compare all →
VariantCapacity factorCost $/MWhgCO₂e/kWhLand m²/MWhDeaths/TWhBuild (yrs)
Concentrated solar (with storage)30–55%70–20027 (8.8–63)22—2–4

Costs come from IRENA 2023 cost report (published 2024) on renewable power generation, project ranges. IPCC AR5 WGIII Annex III supplies the emissions (median, min–max). Death rates are Markandya & Wilkinson (2007) and Sovacool et al. (2016), reached via Our World in Data.

CSP, sometimes called solar thermal electricity, captures the sun’s heat where PV captures its light. Mirrors follow the sun and aim its beam at a receiver, warming a working fluid to 300–565 °C. Steam from that fluid spins a turbine of the kind used in coal and gas stations. What sets it apart is storage. A tank of molten salt holds heat at a fraction of what holding electricity costs, so the plant can deliver solar energy at night.

It remains a small industry. In the mid-2020s only about 7 GW operated (IRENA, REN21, SolarPACES); solar PV passes 2,000 GW. Ember and Our World in Data list no separate CSP line, so it is buried in solar totals, well below 1%. Its value is qualitative: dispatchable, storable solar power for sunny, dry countries.

What every plant contains

  1. Solar field. Heliostats or curved troughs follow the sun, focusing direct normal irradiance. Concentration is about 30-100 suns for line-focus fields and 500-1,000+ for point-focus towers.
  2. Receiver. Absorbs the light. The heat goes into synthetic oil, molten nitrate salt, or water that boils straight to steam.
  3. Heat storage (thermal energy storage). Usually a cold tank and a hot tank filled with “solar salt” (about 60% sodium nitrate, 40% potassium nitrate). Salt leaves the cold tank at roughly 290 °C, picks up heat, and is stored hot at ~390 °C (troughs) or ~565 °C (towers).
  4. Power block. Turbine, generator and condenser in a Rankine cycle, essentially a fossil plant’s engine room.

Only direct beam light can be focused. Cloud haze that PV still tolerates kills CSP output, so what counts for site choice is DNI rather than global horizontal irradiance; the solar potential map shows it.

The four layouts

Parabolic trough

A curved mirror trough focuses light on an evacuated pipe along its focal line; synthetic oil inside reaches about 390-400 °C. This is the most proven layout and the bulk of installed capacity. Look at Spain’s 50 MW series (Andasol 1-3, 7.5 hours of storage each), Solana in Arizona (280 MW), and the 600 MW trough block within Phase 4 of Dubai’s Mohammed bin Rashid Al Maktoum Solar Park. Oil limits the steam temperature, hence efficiency, and salt storage requires an extra oil-to-salt heat exchanger.

Central receiver (solar power tower)

Thousands of flat heliostats, each with its own tracking drive, send light to the top of a tower. Temperatures are higher (salt around 565 °C), so turbines run more efficiently, and the salt flows straight into storage without an exchanger, cutting storage cost. Morocco’s Noor III has 150 MW; Chile’s Cerro Dominador, 110 MW with about 17.5 h of storage; Dubai’s 100 MW tower stands 262 metres high, the tallest ever built for solar. California’s Ivanpah (about 390 MW gross, three towers, direct steam) has no storage and is the best-known example of that choice.

Linear Fresnel

Nearly flat mirror strips lie close to the ground and aim at a fixed receiver overhead. Their cost and land use per MW undercut troughs, but optical performance suffers, particularly in winter and far from the equator. Plants are normally in the tens of MW: Spain’s Puerto Errado 2 (30 MW) and India’s Dhursar (125 MW).

Parabolic dish

One dish, one receiver at the focus, usually a Stirling engine rated about 10-25 kW. Dish-Stirling machines hold the efficiency record for solar-to-electric conversion, above 30% at peak. Storage is awkward, and the concept never became commercial; large US dish projects from the early 2010s were scrapped or turned into PV.

Technology Operating temperature Concentration Annual solar-to-electric efficiency Storage integration Maturity
Parabolic trough 390-400 °C (oil) 70-100 suns ~13-16% Indirect molten salt Most deployed
Power tower 500-565 °C (salt) 500-1,000+ suns ~15-20% Direct molten salt Commercial, growing
Linear Fresnel 250-500 °C 25-100 suns ~8-12% Limited Early commercial
Parabolic dish 650-750 °C (engine) 1,000-3,000 suns ~20-25% (claimed) Difficult Demonstration

Figures are rough design and operating values drawn from IRENA and SolarPACES publications; DNI, storage size and operating strategy move any single plant away from them.

Efficiency chain and capacity factor

Annual efficiency multiplies several stages. Optics (reflectivity, cosine, shading) pass about 55-75% over a year, the receiver keeps 80-90%, and the steam cycle yields 35-42%. The product, 13-20%, matches or trails PV modules. The upper bound for the power block is set by Carnot:

η_Carnot = 1 − T_cold / T_hot (temperatures in kelvin)

Example: trough, T_hot = 663 K (390 °C), T_cold = 313 K (40 °C) → η_max ≈ 53% tower, T_hot = 838 K (565 °C), T_cold = 313 K → η_max ≈ 63%

Solar multiple SM = thermal power of solar field at design point / thermal input of power block

Hence the preference for towers in new projects. Dispatchability is controlled by the solar multiple: at SM = 1, noon sun only just fills the turbine; at 2.5-3.5, surplus heat goes into storage for evening and night. A salt tank sheds just a few percent of its heat per day and costs far less per stored kWh than a battery, so 6-15 hours is standard.

The capacity factor follows storage size: about 20-30% unstored, 40-55% typical with 7-10 hours at good sites, 60-70% or more for designs such as Cerro Dominador. In IRENA’s data the weighted average for new plants climbed from about 30% in 2010 to 40-55% lately. The capacity factor calculator turns this into yearly output.

Costs

CSP got cheaper quickly too, though starting higher and with far fewer plants than PV.

  • IRENA (2024): the weighted-average LCOE of new CSP dropped about 70%, from USD 0.39/kWh (2010) to roughly USD 0.12/kWh (2023). With so few commissionings a year (lately mostly Chinese), the annual average swings.
  • Tenders: in 2017 Dubai contracted the 950 MW Noor Energy 1 (Phase 4: 700 MW CSP plus 250 MW PV, 15 hours storage) at about USD 0.073/kWh. Chilean and Chinese bids range USD 0.06-0.11/kWh, depending on finance and support.
  • Lazard LCOE+: US towers with storage, USD 120-160/MWh without subsidy, far above utility PV.
  • NREL ATB: NREL models further large declines for molten-salt towers, provided next-generation designs (hotter receivers, supercritical CO2 cycles) reach the market.

Plants cost several thousand USD per kW, rising with storage hours, and LCOE responds to WACC, plant size and DNI. Compare CSP not with bare PV but with PV plus battery storage supplying the same evening and night energy. Two to four hours: PV and lithium-ion win almost anywhere. Eight hours and up, or industrial heat: CSP looks better. The LCOE calculator lets you test it.

Landmark plants

  • Noor Ouarzazate (Morocco): 580 MW overall. Noor I is 160 MW of trough with 3 h storage; Noor II, 200 MW trough, 7 h; Noor III, 150 MW tower, about 7.5 h; Noor IV, 72 MW PV. Multilateral concessional loans paid for it, and it became the model for big CSP in emerging economies.
  • Cerro Dominador (Chile): first CSP in Latin America (2021). A 110 MW salt tower with about 17.5 h storage and 100 MW of PV, in the Atacama, where DNI ranks among the world’s best.
  • Mohammed bin Rashid Al Maktoum Solar Park Phase 4 (UAE): largest single-site CSP investment: 600 MW trough, 100 MW tower, 250 MW PV, 15 hours of storage.
  • Ivanpah (United States): biggest CSP plant when it opened in 2014. Direct steam, no storage, natural gas for start-up. Early output fell short and bird deaths drew criticism. In 2025 its offtakers agreed to wind down contracts before a planned partial closure.
  • Crescent Dunes (United States): 110 MW tower, 10 h storage. A salt tank leak and long outages chilled investor appetite for CSP in the late 2010s.

Land, water, materials

  • Land: 2-4 hectares per MW, equal to or a bit above utility PV when the oversized storage field counts. The ground must be level, with slopes generally under 1-3%.
  • Water: the biggest environmental problem in deserts. Wet-cooled troughs consume about 3,000-3,500 litres per MWh, like coal plants. Air cooling saves around 90%, leaving a few hundred litres per MWh for mirror washing and steam make-up, in exchange for a few percent of output and extra capital. Most new plants in dry regions use it.
  • Materials: lots of steel and concrete, glass and silver for mirrors, tens of thousands of tonnes of nitrate salt per plant. None is scarce, but mass per MW exceeds PV.

Life-cycle CO2

  • IPCC AR5 WGIII Annex III (2014): median 27 gCO2e/kWh, range 8.8-63 g.
  • UNECE (2021): higher than PV on average, due to steel, concrete, glass, nitrate salt and, in some designs, natural gas for start-up and freeze protection. Still about ten times below fossil power.

Gas matters most. Plants that burn plenty of gas to start or to keep salt liquid emit visibly more in operation than solar-only plants. Molten salt solidifies near 220-240 °C, so cloudy stretches require heating it.

Hazards

Standard thermal-plant risks apply: steam at high pressure, hot fluids, and fire from synthetic oil in troughs. Birds and insects flying through the beam near tower receivers may be burned; published estimates of bird deaths at Ivanpah differ a lot. Glare can trouble pilots and drivers. Nitrate salts are non-toxic fertiliser-grade chemicals, but leaks damage equipment.

Outlook

Falling PV prices stalled CSP in the 2010s; storage is bringing it back. China has a big pipeline of tower and Fresnel plants beside PV and wind, intended to supply firm power to remote “clean energy bases”. Chile, Morocco, Saudi Arabia, the UAE and South Africa stay active. Expect CSP to cover evenings and nights beside cheap PV and to supply high-temperature industrial heat, since the field can make steam directly. R&D targets receivers above 700 °C, supercritical CO2 cycles and particle storage. For the PV side, see solar power; for cost and emissions against alternatives, the technology comparison.

Frequently asked questions

What does concentrated solar power mean?
A field of mirrors aims sunlight at a receiver; inside, a fluid heats up to several hundred degrees Celsius. A normal steam turbine then turns that heat into electricity. Since molten salt stores heat cheaply, the plant can go on generating well into the night.
What is the total CSP capacity in the world?
IRENA and REN21 count about 7 GW in the mid-2020s, tiny beside the 2,000 GW and more of solar PV. Spain has the biggest fleet (about 2.3 GW), with the United States next. China, Morocco, the UAE, South Africa and Chile are where new plants appear.
What is the cost of CSP power?
Per IRENA, the global weighted-average LCOE of newly commissioned plants fell from about USD 0.39/kWh in 2010 to roughly USD 0.12/kWh in 2023. Auctions that include long storage clear at about USD 0.07-0.10/kWh (Dubai's Noor Energy 1: 7.3 US cents/kWh). A PV kWh is still cheaper.
Why did PV outgrow CSP?
PV modules got cheap much faster, and PV works in any size, from a rooftop upward. CSP means large projects, strong direct sunlight and demanding engineering. Early plants like Crescent Dunes and Ivanpah underdelivered. Its remaining strength is low-cost heat storage over long durations.
How many hours of storage can CSP offer?
Designers of new tower and trough plants usually specify molten-salt tanks that run the turbine at full load for 6-15 hours. Chile's Cerro Dominador has about 17.5 hours, which allows 24-hour operation on many days.
Which regions suit CSP?
The deciding number is direct normal irradiance (DNI). Aim for 1,900-2,000 kWh/m² per year at the least, and above 2,500 if possible. That means arid, cloud-free places: Chile's Atacama Desert, North Africa, the Middle East, southern Spain, the US Southwest, western China, South Africa and Australia.

Sources & references

  1. IRENA (2024). Renewable Power Generation Costs in 2023
  2. NREL / SolarPACES. Concentrating Solar Power Projects database
  3. REN21. Renewables Global Status Report
  4. IPCC (2014). AR5 WGIII Annex III: Technology-specific Cost and Performance Parameters
  5. UNECE (2021). Life Cycle Assessment of Electricity Generation Options
  6. NREL. Annual Technology Baseline (ATB)